Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system.

作者信息

Rüfer Florian, Schröder Anke, Bader Christine, Erb Carl

机构信息

Department of Ophthalmology, University Hospital of Kiel, Kiel, Germany.

出版信息

Cornea. 2007 Jan;26(1):1-5. doi: 10.1097/01.ico.0000240095.95067.3f.

Abstract

PURPOSE

The thickness of corneal tissue is an important parameter in refractive surgery, Goldmann applanation tonometry, and corneal diseases. The purpose of the study was to record system-specific normal values with the Orbscan II system and to investigate the influence of sex and age on central and peripheral corneal thickness to characterize more precisely the anatomy of the cornea.

METHODS

The Orbscan II topography system is a computer-assisted slit-beam scanning technology that can map the anterior section of the eye. It was used to take 2 measurements at 10-minute intervals on 777 eyes of 390 normal white subjects ranging in age between 10 and 80 years. Two hundred forty-two participants were men and 148 were women. The central corneal thickness and the nasal, superior, inferior, and temporal peripheral corneal thickness at a distance of 3 mm from the center were analyzed. No correction factor was used. Using nonparametric test methods, we carried out a statistical analysis of the parameters of sex and age.

RESULTS

The mean central corneal thickness of all 777 eyes was 595 +/- 41 microm. No sex-specific central difference was identifiable (P = 0.33), there was no significant difference between the sides (P = 0.23), and no significant difference was found between the first and second measurement. The group of 10- to 39-year-olds had a mean central corneal thickness of 591 +/- 41 microm, whereas that of 40- to 80-year-olds was 600 +/- 39 microm, which was a significant difference (P = 0.03). The mean peripheral corneal thickness was 689 +/- 46 microm nasally, 688 +/- 42 microm superiorly, 667 +/- 40 microm inferiorly, and 655 +/- 42 microm temporally. Nasally and superiorly, we found a significant negative correlation with age (Spearman rank correlation, P = 0.02).

CONCLUSIONS

The normal values presented here are a suitable reference basis for future studies in whites. Peripheral corneal thickness is asymmetric and seems to undergo age-related anatomic changes. This information should be considered when planning penetrating keratoplasty and refractive surgery.

摘要

目的

角膜组织厚度是屈光手术、Goldmann压平眼压测量法及角膜疾病中的一个重要参数。本研究的目的是记录Orbscan II系统特定的正常值,并研究性别和年龄对中央及周边角膜厚度的影响,从而更精确地描述角膜的解剖结构。

方法

Orbscan II地形图系统是一种计算机辅助裂隙光束扫描技术,可绘制眼部前段图像。该系统用于对390名年龄在10至80岁之间的正常白人受试者的777只眼睛每隔10分钟进行两次测量。其中242名参与者为男性,148名参与者为女性。分析中央角膜厚度以及距中心3 mm处的鼻侧、上方、下方和颞侧周边角膜厚度。未使用校正因子。采用非参数检验方法对性别和年龄参数进行统计分析。

结果

所有777只眼睛的平均中央角膜厚度为595±41微米。未发现性别特异性的中央差异(P = 0.33),两侧之间无显著差异(P = 0.23),第一次和第二次测量之间也未发现显著差异。10至39岁组的平均中央角膜厚度为591±41微米,而40至80岁组为600±39微米,存在显著差异(P = 0.03)。周边角膜平均厚度鼻侧为689±46微米,上方为688±42微米,下方为667±40微米,颞侧为655±42微米。鼻侧和上方,我们发现与年龄呈显著负相关(Spearman等级相关性,P = 0.02)。

结论

此处给出的正常值为未来白人研究提供了合适的参考依据。周边角膜厚度不对称,似乎会发生与年龄相关的解剖学变化。在规划穿透性角膜移植术和屈光手术时应考虑这些信息。