Yilmaz Asude, Baydaş Seyfettin
Department of Prosthetic Dentistry, Faculty of Dentistry, University of Atatürk, Erzurum, Turkey.
J Contemp Dent Pract. 2007 Jan 1;8(1):44-51.
The aim of this study was to evaluate the fracture resistance of various provisional crown materials using an in vitro model test system.
In the present study polycarbonate crowns, prefabricated by the manufacturer (3M Polycarbonate Crown), and the temporary crowns, fabricated in the dental laboratory environment, were fabricated using bis-acryl composite (Protemp II), autopolymerizing PMMA resin (BISICO Temp S), and heat-polymerized PMMA resin (Major C&B-V Dentine). All temporary crowns were stored in distilled water for 24 hours at room temperature prior to testing. The crowns were seated on metal dies, fabricated from Cr-Co alloy (AZ Dental, Konstanz, Germany), and then tested using the indenter of a Hounsfield testing machine (Hounsfield Tensometer, Hounsfield Test Equipment, Raydon, England). The tip of the indenter was located at a position one-third of the way down the inciso-palatine surface at 135 masculine. The data were statistically analyzed for differences using one-way analysis of variance (ANOVA) and the Tukey HSD test (P < .05). Additionally, the types of failure obtained from the fracture load test were examined using 10x magnification with a stereo microscope.
The results of the present study indicated polycarbonate crowns were significantly different from the BISICO Temp S, Protemp II, and Major C&B-V Dentine (P < .05) groups.
This in vitro study shows polycarbonate crowns may be preferable to the other types of temporary crowns used in this study.
本研究旨在使用体外模型测试系统评估各种临时冠材料的抗折性。
在本研究中,由制造商预制的聚碳酸酯冠(3M聚碳酸酯冠)以及在牙科实验室环境中制作的临时冠,分别使用双丙烯酸复合树脂(Protemp II)、自凝PMMA树脂(BISICO Temp S)和热凝PMMA树脂(Major C&B-V Dentine)制作。所有临时冠在测试前于室温下在蒸馏水中储存24小时。将冠放置在由铬钴合金(AZ Dental,德国康斯坦茨)制成的金属代型上,然后使用Hounsfield试验机(Hounsfield张力计,Hounsfield测试设备,英国雷登)的压头进行测试。压头尖端位于腭切端表面向下三分之一处,呈135°角。使用单因素方差分析(ANOVA)和Tukey HSD检验(P < .05)对数据进行统计学差异分析。此外,使用立体显微镜以10倍放大倍数检查从抗折载荷测试中获得的失败类型。
本研究结果表明,聚碳酸酯冠与BISICO Temp S、Protemp II和Major C&B-V Dentine组有显著差异(P < .05)。
这项体外研究表明,聚碳酸酯冠可能比本研究中使用的其他类型临时冠更具优势。