Abstract

The purpose of this paper was to evaluate the results of acetabular revisions with the use of an oblong revision cup that is designed with its longitudinal diameter elongated relative to its transverse diameter. Between 1996 and 2001, 62 hips in 60 patients underwent an acetabular revision with the insertion of a LOR acetabular component. Seven hips were lost to follow-up or the patients died; the remaining 55 hips (53 patients) remained in follow-up for an average of 7.2 years (range: 5.0-10.1 years). One socket was revised for aseptic loosening, and another was operated on for a late polyethylene liner dissociation. The average Harris hip score (HHS) improved from 34 to 79. Results were rated as excellent in 16 hips, good in 28, fair in six and poor in three. Radiographic analysis demonstrated an improvement in the average vertical displacement of the hip centre: 49 hips had a well-fixed, bone-ingrown cup and four had a stable fibrous union. For large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction without the need for bulk structural acetabular bone grafts, provided good clinical results and showed satisfactory stability at the midterm follow-up.

摘要

本文的目的是评估使用一种椭圆形翻修髋臼杯的髋臼翻修结果,该髋臼杯设计为其纵向直径相对于横向直径拉长。1996年至2001年期间,60例患者的62髋接受了髋臼翻修并植入了LOR髋臼组件。7髋失访或患者死亡;其余55髋(53例患者)接受了平均7.2年(范围:5.0 - 10.1年)的随访。1例髋臼因无菌性松动进行了翻修,另1例因聚乙烯内衬晚期分离接受了手术。Harris髋关节评分(HHS)平均从34分提高到79分。结果评为优的有16髋,良的有28髋,可的有6髋,差的有3髋。影像学分析显示髋关节中心平均垂直位移有所改善:49髋有固定良好、骨长入的髋臼杯,4髋有稳定的纤维性骨愈合。对于髋臼上外侧大的骨缺损,该植入物有助于进行复杂的重建,无需大块结构性髋臼骨移植,提供了良好的临床结果,并在中期随访时显示出令人满意的稳定性。

相似文献

1
Acetabular revisions using a cementless oblong cup: five to ten year results.
Int Orthop. 2008 Apr;32(2):189-93. doi: 10.1007/s00264-006-0307-4. Epub 2007 Jan 13.
2
[Limits in cementless hip revision total hip arthroplasty. Midterm experience with an oblong revision cup].
Z Orthop Ihre Grenzgeb. 2003 Mar-Apr;141(2):182-9. doi: 10.1055/s-2003-38652.
3
[Oblong acetabular cup, type TC, for revision total hip arthroplasty].
Acta Chir Orthop Traumatol Cech. 2012;79(6):506-11.
4
Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up.
J Arthroplasty. 2017 Nov;32(11):3495-3501. doi: 10.1016/j.arth.2017.06.026. Epub 2017 Jun 20.
5
[Oblong implants for revision total hip arthroplasty].
Acta Chir Orthop Traumatol Cech. 2009 Dec;76(6):462-72.
6
[Reconstruction of severe acetabular bone defects using Burch-Schneider cage].
Acta Chir Orthop Traumatol Cech. 2006 Jun;73(3):157-63.
7
[Hip joint arthroplasty following surgical treatment of acetabular fracture].
Acta Chir Orthop Traumatol Cech. 2006 Aug;73(4):268-74.
8
Poor results of the cementless total hip arthroplasty with a nonporous coated acetabular component: AcSys Shearer Cup.
J Orthop Sci. 2007 Sep;12(5):466-70. doi: 10.1007/s00776-007-1161-y. Epub 2007 Sep 28.

引用本文的文献

2
Trabecular titanium cups in acetabular revision arthroplasty: analysis of 10-year survivorship, restoration of center of rotation and osteointegration.
Arch Orthop Trauma Surg. 2022 Nov;142(11):3523-3531. doi: 10.1007/s00402-021-04243-x. Epub 2021 Nov 15.
4
Reconstruction options and outcomes for acetabular bone loss in revision hip arthroplasty.
Orthop Rev (Pavia). 2020 Jun 25;12(Suppl 1):8655. doi: 10.4081/or.2020.8655. eCollection 2020 Jun 29.
5
Deeper Central Reaming May Enhance Initial Acetabular Shell Fixation.
Arthroplast Today. 2020 Jun 8;6(3):343-349. doi: 10.1016/j.artd.2020.03.012. eCollection 2020 Sep.
6
Protrusion of a ceramic femoral head through the acetabular metallic cup in total-hip arthroplasty: A case report.
Medicine (Baltimore). 2020 Jun 12;99(24):e20469. doi: 10.1097/MD.0000000000020469.
7
Reconstruction of failed acetabular component in the presence of severe acetabular bone loss: a systematic review.
Musculoskelet Surg. 2019 Apr;103(1):1-13. doi: 10.1007/s12306-018-0539-7. Epub 2018 Apr 13.
8
[Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System].
Orthopade. 2017 Feb;46(2):126-132. doi: 10.1007/s00132-016-3375-1.
9
Satisfying outcomes scores and survivorship achieved with impaction grafting for revision THA in young patients.
Clin Orthop Relat Res. 2015 Dec;473(12):3867-75. doi: 10.1007/s11999-015-4293-y.
10
Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trč-Cingr cup.
Int Orthop. 2014 May;38(5):935-40. doi: 10.1007/s00264-013-2269-7. Epub 2014 Jan 16.

本文引用的文献

2
Management of types III and IV acetabular deficiencies with the longitudinal oblong revision cup.
J Arthroplasty. 2006 Sep;21(6):857-64. doi: 10.1016/j.arth.2005.08.026.
3
Acetabular revision surgery with the LOR cup: three to 8 years' follow-up.
J Arthroplasty. 2006 Jan;21(1):114-21. doi: 10.1016/j.arth.2005.02.017.
4
Structural allograft and primary press-fit cup for severe acetabular deficiency. A minimum 6-year follow-up study.
Int Orthop. 2005 Jun;29(3):135-9. doi: 10.1007/s00264-005-0640-z. Epub 2005 Apr 5.
5
Factors influencing the longer-term survival of uncemented acetabular components used in total hip revisions.
J Bone Joint Surg Am. 2004 Feb;86(2):342-7. doi: 10.2106/00004623-200402000-00018.
6
Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty.
J Bone Joint Surg Am. 2001 Sep;83(9):1352-7. doi: 10.2106/00004623-200109000-00010.
7
Bilobed oblong porous coated acetabular components in revision total hip arthroplasty.
Clin Orthop Relat Res. 2000 Feb(371):154-60. doi: 10.1097/00003086-200002000-00019.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验