Zhao Ding, Zhang De-Bao, Han Dong-Feng, Gu Gui-Shan
Department of Orthopedic Surgery.
Department of Emergency Medicine, The First Hospital of Jilin University, Changchun, Jilin, China.
Medicine (Baltimore). 2020 Jun 12;99(24):e20469. doi: 10.1097/MD.0000000000020469.
Dislocation, wear, metallosis, and implant loosening are well-known complications of a failed total-hip arthroplasty (THA), and acetabular liner dissociation is an uncommon but catastrophic complication. To our knowledge, this is the first description of metallosis due to acetabular liner dissociation, but not presenting as a result of wear of a metal-on-metal articulation and a polyethylene liner of other articulation.
We described a 61-year-old man who had a 2-year history of pain in the right groin region after THA. Postoperative period of primary THA was uneventful. However, he did not undergo postoperative follow-up, and often participated in strenuous sports activities including mountain climbing and long-distance running.
Radiographs demonstrated superior subluxation of the femoral head and direct articulation and abrasion wear of the ceramic femoral head on the cup. Preoperative laboratory data revealed no signs of infection.
We performed revision THA using a direct lateral approach with ceramic-on-ceramic hip prosthesis.
Postoperatively, the patient wore a hip orthosis for 6 weeks to prevent dislocation but was allowed full weight bearing. At 1-year follow-up, there was no recurrence of hip pain.
Wear of THA components can result in catastrophic failure of the implants and significant soft-tissue metallosis. Therefore, regular postoperative follow-up is necessary for early intervention, even in those with asymptomatic hips.
脱位、磨损、金属沉着病和植入物松动是全髋关节置换术(THA)失败的常见并发症,而髋臼衬垫分离是一种罕见但灾难性的并发症。据我们所知,这是首次对髋臼衬垫分离导致的金属沉着病进行描述,而非由金属对金属关节磨损或其他关节的聚乙烯衬垫磨损所致。
我们描述了一名61岁男性,他在全髋关节置换术后右腹股沟区疼痛已有2年。初次全髋关节置换术的术后过程顺利。然而,他未进行术后随访,且经常参加剧烈体育活动,包括爬山和长跑。
X线片显示股骨头向上半脱位,陶瓷股骨头在髋臼杯上直接接触并存在磨损。术前实验室数据未显示感染迹象。
我们采用直接外侧入路,使用陶瓷对陶瓷髋关节假体进行了全髋关节翻修术。
术后,患者佩戴髋关节矫形器6周以防止脱位,但允许完全负重。在1年的随访中,髋关节疼痛未复发。
全髋关节置换术组件的磨损可导致植入物灾难性失败和严重的软组织金属沉着病。因此,即使是无症状髋关节的患者,定期术后随访对于早期干预也是必要的。