Suppr超能文献

一氧化氮弥散能力及其组成部分的短期变异性。

Short-term variability of nitric oxide diffusing capacity and its components.

作者信息

Murias Juan M, Zavorsky Gerald S

机构信息

Department of Anesthesia, McGill University Health Center, Montreal, Quebec, Canada.

出版信息

Respir Physiol Neurobiol. 2007 Aug 1;157(2-3):316-25. doi: 10.1016/j.resp.2006.12.008. Epub 2006 Dec 19.

Abstract

When monitoring nitric oxide diffusing capacity (DL(NO)) in patients, it is necessary to distinguish natural biological variation from a real change in alveolar-membrane conductance. The short-term variability of single-breath DL(NO) has not been established. The aim was to determine the short-term variability DL(NO) in healthy subjects. Twelve healthy subjects performed single-breath hold diffusing capacity tests at rest over a 2-month period (eight separate sessions with 8+/-3 days between each session). Each subject inhaled 41+/-4 ppm NO and a standard diffusion mixture. DL(NO), which is a multiple of the membrane diffusing capacity for carbon monoxide (Dm(CO)), as well as carbon monoxide diffusing capacity (DL(CO)) and pulmonary capillary blood volume (V(c)) remained unaltered over the 2-month period (P>0.05). Reproducibility (calculated as 2.77 multiplied by the within-subject standard deviation) over eight sessions was 20, 5 and 8 mL min(-1)mmHg(-1) for DL(NO), DL(CO) and Dm(CO), respectively, and 19 mL for V(c) (when Dm(CO)=DL(NO)/2.42). DL(NO), DL(CO), Dm(CO) and V(c) remain unchanged over a period of 2 months. Since the inter-session variability is 20, 5 and 8 mL min(-1)mmHg(-1) for DL(NO), DL(CO) and Dm(CO), and 19 mL for V(c), a meaningful change should equal or exceed those values. While there is a small chance that week-to-week variation can also be partly due to mild pathophysiological changes, any differences that are below the reproducibility values are likely to be natural biological variation or technical variation of the equipment, rather than true physiological change.

摘要

在监测患者的一氧化氮弥散能力(DL(NO))时,有必要区分自然生物变异与肺泡膜传导性的实际变化。单次呼吸DL(NO)的短期变异性尚未确定。本研究旨在确定健康受试者中DL(NO)的短期变异性。12名健康受试者在2个月内进行了静息状态下的单次屏气弥散能力测试(共8次独立测试,每次测试间隔8±3天)。每位受试者吸入41±4 ppm的一氧化氮和标准弥散混合气。作为一氧化碳膜弥散能力(Dm(CO))倍数的DL(NO),以及一氧化碳弥散能力(DL(CO))和肺毛细血管血容量(V(c))在2个月期间保持不变(P>0.05)。在8次测试中,DL(NO)、DL(CO)和Dm(CO)的重复性(计算为2.77乘以受试者内标准差)分别为20、5和8 mL min⁻¹mmHg⁻¹,V(c)为19 mL(当Dm(CO)=DL(NO)/2.42时)。DL(NO)、DL(CO)、Dm(CO)和V(c)在2个月内保持不变。由于DL(NO)、DL(CO)和Dm(CO)的测试间变异性分别为20、5和8 mL min⁻¹mmHg⁻¹,V(c)为19 mL,有意义的变化应等于或超过这些值。虽然每周的变化也有小部分可能是由于轻度病理生理变化,但任何低于重复性值的差异可能都是自然生物变异或设备的技术变异,而非真正的生理变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验