近马利特单元中央凹抑制试验:一项建立测试规范并确定其与其他验光测试关系的横断面研究。

The Near Mallett Unit Foveal Suppression Test: a cross-sectional study to establish test norms and relationship with other optometric tests.

作者信息

Tang Sosena T W, Evans Bruce J W

机构信息

Boots Opticians Ltd, 35 Queensway, Stevenage, Herts SG1 1BS, UK.

出版信息

Ophthalmic Physiol Opt. 2007 Jan;27(1):31-43. doi: 10.1111/j.1475-1313.2006.00453.x.

Abstract

When the binocular system comes under prolonged stress in decompensated heterophoria, a small suppression area can develop at the fovea. This foveal suppression (FS) may be an adaptation to eliminate symptoms. The near Mallett unit (NMU) is a hand-held instrument that contains a binocular status test for detecting and quantifying FS. We measured FS in a cross-sectional study of 131 patients to investigate the normal range of responses. A ratio scoring method was devised which considers the number of letters read with dichoptic viewing when binocularly fused (b) and under monocular (m) conditions, using the formula 100 x (m - b)/m. The 95th percentile value of the FS ratios was calculated as the limit of the normal range and this gave a value for the right eye (RE; 33%), left eye (LE; 43%) and total (38%). This result shows that statistically significant FS occurs when a patient can read approximately one line further in the test monocularly, compared to under fused dichoptic conditions. A statistically significant correlation was found between absolute values of horizontal aligning prism (associated heterophoria on the NMU) and FS ratio. Some limitations of the FS test and unexpected results became apparent during our research and an abnormal result on the test does not always indicate a binocular vision anomaly. Nonetheless, we feel that the test can provide useful information when the results are taken in the context of other clinical tests. Our results are used to develop recommendations and clinical guidelines for using the FS test, and to make suggestions for improvements in future designs of the test.

摘要

当双眼系统在失代偿性隐斜中受到长时间压力时,中央凹处可能会形成一个小的抑制区。这种中央凹抑制(FS)可能是一种消除症状的适应性反应。近用马利特单位(NMU)是一种手持仪器,包含用于检测和量化FS的双眼状态测试。我们在一项对131名患者的横断面研究中测量了FS,以调查正常反应范围。设计了一种比率评分方法,该方法考虑了在双眼融合(b)和单眼(m)条件下双眼分视时读出的字母数量,使用公式100×(m - b)/m。计算出FS比率的第95百分位数作为正常范围的界限,得出右眼(RE;33%)、左眼(LE;43%)和总体(38%)的值。该结果表明,与双眼融合分视条件相比,当患者在单眼测试中能够多读大约一行时,就会出现具有统计学意义的FS。发现水平对齐棱镜的绝对值(NMU上的相关隐斜)与FS比率之间存在统计学上的显著相关性。在我们的研究过程中,FS测试的一些局限性和意外结果变得明显,测试结果异常并不总是表明存在双眼视觉异常。尽管如此,我们认为当结合其他临床测试结果时,该测试可以提供有用的信息。我们的结果用于制定使用FS测试的建议和临床指南,并为该测试未来设计的改进提出建议。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验