Chang Ku-Shang, Chang Chen-Kai, Chou Su-Fen, Chen Chien-Yuan
Department of Biochemical Science and Technology, Graduate Institute of Microbiology and Biochemistry, National Taiwan University, Taipei, Taiwan.
Biosens Bioelectron. 2007 Jun 15;22(12):2914-20. doi: 10.1016/j.bios.2006.12.001. Epub 2007 Jan 31.
An l-glutamate biosensor modified by cation exchanger membrane on a palladium (Pd) electrode was designed for the purpose of preventing interferences and electrode fouling during the measurement of serum AST and ALT activities. The rate of signal increase obtained by our sensor for the determination of AST and ALT activity was 0.259 and 0.596 nA/min U(-1)l and the response of the sensor to AST and ALT activity were linear over the range of 8-200 and 8-250 Ul(-1), respectively. Both AST and ALT activities could be measured sequentially by injecting the serum into a solution containing l-aspartate and alpha-ketoglutarate. The rate of current increase was relative to AST activity. The activity of ALT was sequentially determined after addition of l-alanine into the solution. The change in the current increase rate after the addition of l-alanine was proportional to the ALT activity. By using the proposed biosensor, the interference of 1mM ascorbic acid was negligible on a dynamical aminotransferase determination when the dynamic data are taken after the steady state of an elevated baseline has been reached. The proposed l-glutamate biosensor provides adequate sensitivity for the measurement of AST and ALT and is expectable to be applied for rapid blood screening of AST and ALT activity in clinical sample.
设计了一种在钯(Pd)电极上由阳离子交换膜修饰的L-谷氨酸生物传感器,用于在血清谷草转氨酶(AST)和谷丙转氨酶(ALT)活性测定过程中防止干扰和电极污染。我们的传感器用于测定AST和ALT活性所获得的信号增加速率分别为0.259和0.596 nA/min U(-1)l,并且传感器对AST和ALT活性的响应在8 - 200和8 - 250 U l(-1)范围内分别呈线性。通过将血清注入含有L-天冬氨酸和α-酮戊二酸的溶液中,可以依次测量AST和ALT的活性。电流增加速率与AST活性相关。在溶液中加入L-丙氨酸后依次测定ALT的活性。加入L-丙氨酸后电流增加速率的变化与ALT活性成正比。使用所提出的生物传感器,当在达到升高基线的稳定状态后获取动态数据时,1mM抗坏血酸对动态转氨酶测定的干扰可忽略不计。所提出的L-谷氨酸生物传感器为AST和ALT的测量提供了足够的灵敏度,有望用于临床样本中AST和ALT活性的快速血液筛查。