Suppr超能文献

垂直D:圆锥角膜疑似患者中的一种新型地形图模式。

Vertical D: a novel topographic pattern in some keratoconus suspects.

作者信息

Abad Juan Carlos, Rubinfeld Roy S, Del Valle Maria, Belin Michael W, Kurstin Joseph M

机构信息

Laser Eye Center of Miami, Miami, Florida, USA.

出版信息

Ophthalmology. 2007 May;114(5):1020-6. doi: 10.1016/j.ophtha.2006.10.022. Epub 2007 Feb 8.

Abstract

PURPOSE

To describe a novel topographic curvature pattern, vertical D, which was present in some keratoconus suspects. This pattern was detected retrospectively in 2 patients who developed post-LASIK ectasia and prospectively in 4 patients who had other corneal abnormalities suggestive of keratoconus.

DESIGN

Retrospective interventional case series and prospective cross-sectional study.

PARTICIPANTS

After vertical D topographic curvature patterns were noted in 2 patients (3 eyes) who developed post-LASIK ectasia, 1168 consecutive potential refractive surgical candidates (2336 eyes) evaluated at a refractive center were screened to detect this vertical D pattern.

METHODS

Placido disc-based curvature topography, ultrasound pachymetry, and elevation-based Scheimpflug topography were performed on these patients.

MAIN OUTCOME MEASURES

Corneal curvature topographic patterns, central keratometry, inferior-superior and nasal-temporal ratios, skewed radial axis value, Humphrey Atlas PathFinder corneal analysis, corneal thickness, and corneal anterior and posterior elevation.

RESULTS

Four additional patients (7 eyes) with vertical D patterns were found (prevalence, 0.34%). In addition to this vertical D pattern, these patients had central corneal thickness < 500 microm and/or posterior corneal protrusion > 20 microm or positive results on keratoconus detection analyses. The 10 eyes with the vertical D pattern had more horizontal (nasal-temporal ratio) than vertical (inferior-superior ratio) curvature asymmetry: 0.98+/-0.04 diopters versus 0.44+/-0.2 diopters (paired t test, P<0.001).

CONCLUSIONS

We propose that vertical D is a novel corneal curvature pattern reflecting horizontal asymmetry that was present in keratoconus suspect patients even if standard keratoconus analyses' results were negative.

摘要

目的

描述一种新型的地形图曲率模式——垂直D,其存在于一些圆锥角膜疑似患者中。在2例发生准分子激光原位角膜磨镶术(LASIK)后角膜扩张的患者中进行回顾性检测,并在4例有其他提示圆锥角膜的角膜异常患者中进行前瞻性检测。

设计

回顾性干预病例系列和前瞻性横断面研究。

参与者

在2例(3只眼)发生LASIK后角膜扩张的患者中发现垂直D地形图曲率模式后,对在屈光中心接受评估的1168例连续潜在屈光手术候选者(2336只眼)进行筛查以检测这种垂直D模式。

方法

对这些患者进行基于普拉西多盘的曲率地形图、超声测厚以及基于高度的眼前节分析系统地形图检查。

主要观察指标

角膜曲率地形图模式、中央角膜曲率、上下和鼻颞比率、倾斜的径向轴值、汉弗莱角膜分析图谱、角膜厚度以及角膜前后表面高度。

结果

另外发现4例(7只眼)有垂直D模式(患病率为0.34%)。除这种垂直D模式外,这些患者中央角膜厚度<500微米和/或角膜后表面突出>20微米,或者圆锥角膜检测分析结果为阳性。有垂直D模式的10只眼中水平(鼻颞比率)曲率不对称比垂直(上下比率)曲率不对称更明显:0.98±0.04屈光度对0.44±0.2屈光度(配对t检验,P<0.001)。

结论

我们提出垂直D是一种新型的角膜曲率模式,反映了即使标准圆锥角膜分析结果为阴性的圆锥角膜疑似患者中存在的水平不对称。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验