Brusini P, Zeppieri M, Tosoni C, Parisi L, Felletti M, Salvetat M L
Department of Ophthalmology, S. Maria della Misericordia Hospital, Udine, Italy.
Eye (Lond). 2008 Mar;22(3):406-13. doi: 10.1038/sj.eye.6702654. Epub 2007 Feb 16.
To compare Stratus-OCT measurements in controls, ocular hypertensive (OHT) patients with (FDT+) and without (FDT-) frequency-doubling technology (FDT) abnormalities, and in patients affected with early primary open-angle glaucoma (POAG).
Thirty-two controls, 78 OHT patients (38 FDT- and 40 FDT+), and 45 early POAG patients (six FDT- and 39 FDT+) underwent the following tests within 3 months: standard automated perimetry (SAP) HFA 30-2; FDT N-30-F; and, Stratus-OCT imaging with retinal nerve fibre layer (RNFL) and optic nerve head (ONH) scans. One eye per patient was considered. Differences among groups were evaluated using the Kruskal-Wallis, analysis of variance, and Duncan's tests.
There were no significant differences in all Stratus-OCT parameters between POAG and OHT FDT+ patients. Statistically significant differences were found between the control group and both the POAG and OHT FDT+ groups for 15 of the 21 Stratus-OCT parameters. Control eyes compared to OHT FDT- showed significant differences in 13 of the 21 parameters. The comparison between the OHT FDT- group, and both the POAG and OHT FDT+ group resulted in 13 of the 21 parameters to be significantly different.
Stratus-OCT seems to show a higher ability in detecting significant differences between healthy, OHT, and early POAG eyes when compared to SAP and FDT. This suggests that the Stratus-OCT could show structural abnormalities before SAP or FDT visual field defects appear in patients at risk of developing glaucoma, which may be beneficial in making therapeutic decisions, especially in OHT patients.
比较Stratus-OCT在正常对照组、伴有(FDT+)和不伴有(FDT-)倍频技术(FDT)异常的高眼压症(OHT)患者以及早期原发性开角型青光眼(POAG)患者中的测量结果。
32名正常对照者、78名高眼压症患者(38名FDT-和40名FDT+)以及45名早期POAG患者(6名FDT-和39名FDT+)在3个月内接受了以下检查:标准自动视野计(SAP)HFA 30-2;FDT N-30-F;以及采用视网膜神经纤维层(RNFL)和视神经乳头(ONH)扫描的Stratus-OCT成像。每位患者选取一只眼进行分析。采用Kruskal-Wallis检验、方差分析和Duncan检验评估组间差异。
POAG患者和OHT FDT+患者的所有Stratus-OCT参数均无显著差异。在21项Stratus-OCT参数中的15项上,正常对照组与POAG组和OHT FDT+组之间存在统计学显著差异。与OHT FDT-组相比,正常对照眼在21项参数中的13项上存在显著差异。OHT FDT-组与POAG组和OHT FDT+组之间的比较显示,21项参数中的13项存在显著差异。
与SAP和FDT相比,Stratus-OCT似乎在检测健康眼、OHT眼和早期POAG眼之间的显著差异方面具有更高的能力。这表明,在青光眼高危患者中,Stratus-OCT可能在SAP或FDT视野缺损出现之前就显示出结构异常,这可能有助于做出治疗决策,尤其是在OHT患者中。