Suppr超能文献

内皮功能的非侵入性评估。观察者内和观察者间的变异性。

Non-invasive assessment of endothelial function. Intra and inter-observer variability.

作者信息

González Arturo Sotomayor, Kostine Andrea, Gómez-Flores Jorge R, Márquez Manlio F, Hermosillo Antonio G, París Juan Verdejo, Torres Pedro Iturralde, Lizalde Luis Colín, Townsend Santiago Nava, Cárdenas Manuel

机构信息

Electrocardiology Department, Instituto Nacional de Cardiologia lgnacio Chávez, México, D.F

出版信息

Arch Cardiol Mex. 2006 Oct-Dec;76(4):397-400.

Abstract

BACKGROUND AND OBJECTIVES

Non-invasive evaluation of endothelial function with high resolution ultrasound has become a widely accepted tool in determination of high risk subjects for early atherosclerosis. Despite its simple appearance, ultrasonographic assessment of brachial artery changes, is technically challenging and has a significant learning curve. In the present study, we evaluate the intra and inter-observer variability in assessing peripheral endothelial function with high resolution ultrasound at a tertiary referral center.

METHODS

Assessment of endothelial function was performed by 2 physicians in 20 volunteers without evidence of coronary artery disease. Endothelial function is evaluated with a high frequency bidimensional ultrasound with a 10.0-MHz linear-array transducer used for the study. Each volunteer was examined by both observers using an identical protocol, measuring brachial artery diameter on three occasions.

RESULTS

Excellent correlation was observed for all brachial artery measures with a Spearman's correlation coefficient > 0.9 (p < 0.0001). Flow-mediated dilation (FMD) in the study population was of 10.45+/-6.9%. Flow independent dilation (FID) was of 24.35+/-7.63%. Intra-observer variability was of 2.1% for observer A and 1.1 % for observer B.

CONCLUSIONS

Non-invasive assessment of endothelial function using brachial artery ultrasound is reproducible and can be performed with low intra and inter-observer variability.

摘要

背景与目的

高分辨率超声对内皮功能进行无创评估已成为确定早期动脉粥样硬化高危人群的广泛认可的工具。尽管其外观简单,但超声评估肱动脉变化在技术上具有挑战性且存在显著的学习曲线。在本研究中,我们在一家三级转诊中心评估了使用高分辨率超声评估外周内皮功能时观察者内和观察者间的变异性。

方法

由两名医生对20名无冠状动脉疾病证据的志愿者进行内皮功能评估。使用用于该研究的10.0兆赫线性阵列换能器的高频二维超声评估内皮功能。两名观察者按照相同方案对每名志愿者进行检查,三次测量肱动脉直径。

结果

所有肱动脉测量值均呈现出极佳的相关性,Spearman相关系数>0.9(p<0.0001)。研究人群中的血流介导的血管舒张(FMD)为10.45±6.9%。非血流依赖性血管舒张(FID)为24.35±7.63%。观察者A的观察者内变异性为2.1%,观察者B为1.1%。

结论

使用肱动脉超声对外周内皮功能进行无创评估具有可重复性,且观察者内和观察者间变异性较低。