使用Amplatzer动脉导管封堵器经导管闭合中至大型动脉导管未闭。

Transcatheter closure of moderate to large patent ductus arteriosus with the Amplatzer duct occluder.

作者信息

Wang Jou-Kou, Wu Mei-Hwan, Hwang Juey-Jen, Chiang Fu-Tein, Lin Ming-Tai, Lue Hung-Chi

机构信息

Department of Pediatrics, National Taiwan University Hospital, Taipei, Taiwan.

出版信息

Catheter Cardiovasc Interv. 2007 Mar 1;69(4):572-8. doi: 10.1002/ccd.20701.

Abstract

OBJECTIVES

To investigate the acute and follow-up results of transcatheter closure of moderate to large patent ductus arteriosus (PDA) with the Amplatzer duct occluder.

METHODS

Between April 2000 and June 2005, 237 patients underwent attempted transcatheter closure of PDA, of whom Amplatzer duct occluder was used in 68 patients with moderate-to-large-sized PDA (45 females, with ages ranging from 56 days to 75 years, median 3.3 years). Moderate to large PDA is defined as ductus diameter > or =2.5 mm (> or =3 mm in early phase of this study) in infants and young children, or > or =4 mm in adolescents and adults. The size of device selected was generally at least 1-2 mm larger than ductus diameter.

RESULTS

The ductus diameter ranged from 2.5 to 8.5 mm (4.1 +/- 1.3 mm). Amplatzer duct occluder was successfully deployed in 66 out of 68 patients. The size of device deployed ranged from 4 to 12 mm (6.3 +/- 1.6 mm). The causes of failure in the 2 patients included calcification of ductus resulting, in failure in advancing a sheath to descending aorta in 1 and kinking of a Cook sheath in the other. Distal embolization of the device occurred several hours later in one. After the device was retrieved percutaneously, the patient was sent to surgery. No other significant complications occurred. In the 3-month follow-up, complete occlusion was achieved in all patients. No patient had left pulmonary artery stenosis.

CONCLUSIONS

Transcatheter closure of moderate-to-large-sized ductus with Amplatzer ductus occluder is effective and safe.

摘要

目的

探讨应用Amplatzer动脉导管封堵器经导管闭合中大型动脉导管未闭(PDA)的急性期及随访结果。

方法

2000年4月至2005年6月,237例患者尝试经导管闭合PDA,其中68例中大型PDA患者(45例女性,年龄56天至75岁,中位年龄3.3岁)使用了Amplatzer动脉导管封堵器。中大型PDA定义为婴幼儿导管直径≥2.5mm(本研究早期为≥3mm),青少年及成人导管直径≥4mm。所选封堵器尺寸一般比导管直径至少大1 - 2mm。

结果

导管直径2.5至8.5mm(4.1±1.3mm)。68例患者中66例成功植入Amplatzer动脉导管封堵器。植入封堵器尺寸4至12mm(6.3±1.6mm)。2例失败原因,1例为导管钙化致鞘管无法送入降主动脉,另1例为Cook鞘管扭曲。1例术后数小时发生封堵器远端栓塞,经皮取出封堵器后患者接受手术治疗。无其他严重并发症发生。3个月随访时,所有患者均实现完全封堵,无患者发生左肺动脉狭窄。

结论

应用Amplatzer动脉导管封堵器经导管闭合中大型动脉导管未闭有效且安全。