Abstract

PURPOSE

Videokeratography (VK) has been a widespread technology for corneal surface analysis since the mid-80s. The objective of this study was to develop different techniques for Plácido image edge detection and compare the results of each algorithm in terms of the consequences for axial curvature computations.

METHODS

Plácido images from an Eyesys system 2000 were captured for 4 different spherical surfaces. Each image was saved in bitmap format at the hard disk of an IBM computer. Six different image-processing algorithms were developed using different techniques well-documented in the literature. The six methods were as follows: (1) First order numerical derivative, (2) First and (3) Second order Fourier derivative, (4) the Marr-Hildreth filter, (5) Canny's Method, (6) Mathematical morphology. Each algorithm was tested on each of the Plácido images.

RESULTS

Edge radial distance from center of Plácido image was compared for each algorithm and a computer simulation of the videokeratography system. Mean deviation in terms of pixels/millimeters/dioptric power for all spheres for methods (1)-(6) were, respectively: (1) 33.1695/0.7961/0.79, (2) 32.79/0.7870/0.7724, (3) 60.7150/1.4572/1.4192, (4)18.97/0.4553/0.4572, (5) 46.33/1.1119/1.0917, (6) 20.55/0.4932/0.48.

CONCLUSION

Researchers and clinical ophthalmologists should be more careful when choosing commercial videokeratographs and also when comparing measurements of different instruments, given that there may be differences associated with the image processing technique. We have shown here that the Marr/Hildreth (method (4)) image processing method is more precise than other methods such as Fourier or first order numerical methods.

摘要

相似文献

1
[Different techniques for Plácido image analysis may improve precision of videokeratography].
Arq Bras Oftalmol. 2005 Nov-Dec;68(6):797-805. doi: 10.1590/s0004-27492005000600016.
3
Mumford-Shah algorithm applied to videokeratography image processing and consequences to refractive power values.
Comput Methods Programs Biomed. 2007 Jul;87(1):61-7. doi: 10.1016/j.cmpb.2007.04.002. Epub 2007 May 24.
5
Videokeratoscopes for dioptric power measurement during surgery.
J Cataract Refract Surg. 2002 Nov;28(11):2006-16. doi: 10.1016/s0886-3350(02)01447-5.
7
[An algorithm of corneal reconstruction based on precise location of corneal center].
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011 Oct;28(5):872-5, 885.
8
Enhancing the standard operating range of a Placido disk videokeratoscope for corneal surface estimation.
IEEE Trans Biomed Eng. 2009 Mar;56(3):800-9. doi: 10.1109/TBME.2008.2005997.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验