Glatard Tristan, Pennec Xavier, Montagnat Johan
INRIA Sophia - Projet Asclepios, 2004 Route des Lucioles BP 93 06902 Sophia Antipolis Cedex, France.
Med Image Comput Comput Assist Interv. 2006;9(Pt 2):152-60. doi: 10.1007/11866763_19.
Evaluating registration algorithms is difficult due to the lack of gold standard in most clinical procedures. The bronze standard is a real-data based statistical method providing an alternative registration reference through a computationally intensive image database registration procedure. We propose in this paper an efficient implementation of this method through a grid-interfaced workflow enactor enabling the concurrent processing of hundreds of image registrations in a couple of hours only. The performances of two different grid infrastructures were compared. We computed the accuracy of 4 different rigid registration algorithms on longitudinal MRI images of brain tumors. Results showed an average subvoxel accuracy of 0.4 mm and 0.15 degrees in rotation.
由于大多数临床程序缺乏金标准,评估配准算法具有一定难度。青铜标准是一种基于真实数据的统计方法,通过计算密集型的图像数据库配准程序提供替代的配准参考。在本文中,我们提出了一种通过网格接口工作流执行器对该方法进行高效实现的方式,该执行器能够在短短几个小时内并发处理数百次图像配准。我们比较了两种不同网格基础设施的性能。我们计算了4种不同刚体配准算法在脑肿瘤纵向MRI图像上的准确性。结果显示平均亚体素精度为0.4毫米,旋转精度为0.15度。