Suppr超能文献

Comparison of iohexol 300 and diatrizoate meglumine 60 for body CT: image quality, adverse reactions, and aborted/repeated examinations.

作者信息

Bernardino M E, Fishman E K, Jeffrey R B, Brown P C

机构信息

Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.

出版信息

AJR Am J Roentgenol. 1992 Mar;158(3):665-7. doi: 10.2214/ajr.158.3.1739017.

Abstract

Six hundred patients were prospectively randomized and given either diatrizoate meglumine 60 or iohexol 300 during dynamic contrast-enhanced body CT in order to compare image quality, contrast reactions, and the number of aborted studies or studies in which images had to be repeated. Three hundred two patients received iohexol 300, and 298 patients received diatrizoate meglumine 60. Thirty-nine percent (119/302) of the patients given iohexol 300 and 63% (188/298) of the patients given diatrizoate meglumine 60 had at least one adverse reaction thought to be related to contrast material during, or within 24 hr of, the body CT scan. When reactions of discomfort (heat or warmth, flushing, bad taste) were excluded, 16% (48/302) of the patients who received iohexol and 33% (99/298) of the patients who were given diatrizoate meglumine 60 had at least one adverse reaction. The differences in both types of reactions between the two agents were significant (p less than .001). Among scans evaluated for study quality, 71% (214/302) of the iohexol 300 group and 62% (184/298) of the diatrizoate meglumine 60 group had optimal enhancement (p = .02). However, when the optimal and adequate categories were combined, 301 of 302 patients given iohexol 300 and 292 of 298 patients given diatrizoate meglumine 60 had diagnostic-quality studies (no statistical difference). Studies were not terminated nor were images repeated in 97% (292/302) of the patients given iohexol 300 and in 94% (280/298) of those given diatrizoate meglumine 60. The CT study was repeated because of movement during the contrast injection or aborted because of contrast-related reactions in 0.7% of the patients given iohexol 300 and in 3.0% of the patients given diatrizoate meglumine 60. This difference was statistically significant (p = .04). Our results suggest that the difference in image quality, number of adverse reactions, and number of aborted/repeated CT scans performed with iohexol 300 or diatrizoate meglumine 60 are not sufficiently different to warrant conversion to nonionic agents for body CT scans.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验