Font Guillermina, Juan-García Ana, Picó Yolanda
Laboratori de Bromatologia i Toxicologia, Facultat de Farmàcia, Universitat de València, Av. Vicent Andrés Estellés s/n, 46100 Burjassot, València, Spain.
J Chromatogr A. 2007 Aug 3;1159(1-2):233-41. doi: 10.1016/j.chroma.2007.03.062. Epub 2007 Mar 21.
A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitoring (SRM) mode, were carried out to achieve the required number of identification points according to the 2002/657/EC European Decision. For the quantification in pork tissue samples, a pressurized liquid extraction (PLE) procedure, using hot water as extractant followed by an Oasis HLB cleanup, was developed. Linearity (r between 0.996 and 0.997), precision (RSD<14 %) and recoveries (from 76 to 98%) were satisfactory. The limits of detection and quantification (below 12.5 and 46.5 microg kg(-1), respectively) were in all cases lower than the maximum residue limits (MRLs), indicating the potential of CE-MS2 for the analysis of SAs, in the food quality and safety control areas.
本文提出了一种基于毛细管电泳-串联质谱(CE-MS2)的新型分析方法,并对其进行了验证,用于猪肉中12种磺胺类药物(SAs)的鉴定和同时定量分析。所研究的磺胺类药物包括磺胺噻唑、磺胺嘧啶、磺胺甲氧嗪、磺胺脒、磺胺、磺胺二甲氧嘧啶、磺胺吡啶、磺胺氯哒嗪、磺胺异恶唑、柳氮磺胺吡啶、磺胺苯甲酰胺和磺胺二甲嘧啶。对不同参数(即分离缓冲液、鞘液、电喷雾条件)进行了优化,以获得合适的CE分离效果和高MS灵敏度。使用离子阱作为分析仪,在选择反应监测(SRM)模式下进行MS2实验,以根据2002/657/EC欧洲决议获得所需数量的鉴定点。对于猪肉组织样品的定量分析,开发了一种加压液体萃取(PLE)方法,使用热水作为萃取剂,随后进行Oasis HLB净化。线性(r在0.996至0.997之间)、精密度(RSD<14%)和回收率(76%至98%)均令人满意。所有情况下的检测限和定量限(分别低于12.5和46.5μg kg-1)均低于最大残留限量(MRLs),表明CE-MS2在食品质量和安全控制领域分析磺胺类药物方面具有潜力。