Smith Grace, Clark John M
Heart Center, Division of Pediatric Cardiology, Akron Children's Hospital, Akron, Ohio 44308, USA.
Pacing Clin Electrophysiol. 2007 Apr;30(4):510-8. doi: 10.1111/j.1540-8159.2007.00701.x.
The aim of this study was to quantify fluoroscopy use in catheter ablation procedures using a three-dimensional mapping system as the primary source of catheter guidance.
Three-dimensional mapping allows continuous visualization of the location of mapping and ablation catheter electrodes. It has been shown to decrease fluoroscopy times. However, the extent to which it can decrease fluoroscopy time has not been completely defined.
Thirty patients (mean age 12.9 years; range 4-27 years) with reentrant supraventricular tachycardia underwent catheter ablation using standard protocols. Mapping was performed using the EnSite system (St. Jude Medical, St Paul, MN, USA) in the NavX mode (NavX). Eighteen patients had AVNRT, 12 had AVRT. Fluoroscopy times were compared to an age-matched and rhythm-matched control population.
Procedural success was achieved in 30 of 30 patients (100%). Mean procedure time was 3.27 hours (range 1.83-5.8 hours). Mean fluoroscopy time was 1.05 minutes (range 0-14.8 minutes). Twenty-four of 30 (80%) received no fluoroscopy. Mean fluoroscopy time for the control group was 21.37 minutes (range 5.13-77.13 minutes). Thus fluoroscopy time was 95% less in the study group compared to control (1.05 +/- 2.96 vs 21.37 +/- 18.35 minutes, P < 0.001).
NavX was used to effectively guide catheters during ablation procedures resulting in a significant decrease in fluoroscopy use. In 80% of the procedures, no fluoroscopy was used. Further advances in the technology may permit additional decreases in x-ray exposure for the 20% of patients who required it.
本研究旨在量化在使用三维标测系统作为导管引导主要来源的导管消融手术中透视的使用情况。
三维标测可连续显示标测和消融导管电极的位置。已证明其可减少透视时间。然而,其能减少透视时间的程度尚未完全明确。
30例(平均年龄12.9岁;范围4 - 27岁)折返性室上性心动过速患者按照标准方案接受导管消融。使用圣犹达医疗公司(美国明尼苏达州圣保罗)的EnSite系统在NavX模式下进行标测。18例为房室结折返性心动过速,12例为房室折返性心动过速。将透视时间与年龄匹配和心律匹配的对照组进行比较。
30例患者中有30例(100%)手术成功。平均手术时间为3.27小时(范围1.83 - 5.8小时)。平均透视时间为1.05分钟(范围0 - 14.8分钟)。30例中有24例(80%)未接受透视。对照组的平均透视时间为21.37分钟(范围5.13 - 77.13分钟)。因此,研究组的透视时间比对照组减少了95%(1.05±2.96对21.37±18.35分钟,P < 0.001)。
在消融手术中,NavX被有效用于引导导管,导致透视使用显著减少。80%的手术未使用透视。该技术的进一步发展可能会使另外20%需要透视的患者的X线暴露进一步减少。