Analysis of internal jugular vein insufficiency--a comparison of two ultrasound methods.

作者信息

Nedelmann Max, Teschner Daniel, Dieterich Marianne

机构信息

Department of Neurology, Johannes Gutenberg University, Mainz, Germany.

出版信息

Ultrasound Med Biol. 2007 Jun;33(6):857-62. doi: 10.1016/j.ultrasmedbio.2007.01.001. Epub 2007 Apr 18.

Abstract

Jugular venous valve insufficiency is a contributing factor to different pathologic conditions. For assessment of insufficiency, two ultrasound techniques have been developed, that are based on very different methodology (direct Doppler assessment versus air contrast ultrasound venography [ACUV]). This study was conducted to compare these two methods to improve comparability of existing studies and diagnostic accuracy in future studies. The function of 40 valves was determined in 20 individuals during a Valsalva maneuver. For direct Doppler assessment, valvular competence was assessed on basis of Doppler recordings, following recently established criteria. Valvular insufficiency in ACUV was diagnosed when reflux of an air-based echo contrast agent through the valve could be detected. With both methods, evaluation of 39 valves was accomplished (one exclusion due to hypoplasia of the corresponding vein). Both methods showed very high agreement in detection rates. All 18 valves being classified as insufficient by Doppler criteria were also insufficient in ACUV. Of 21 valves classified as competent (Doppler), one valve was rated as insufficient in ACUV due to discrete reflux of microbubbles. However, ACUV was inaccurate in evaluation of the left internal jugular vein after injection of the contrast agent into the right cubital vein. High detection rates could only be achieved when this was taken into account. This study shows that detection rates of internal jugular valve insufficiency are very similar with both methods. However, this high agreement required modification of the established protocol of ACUV.

摘要

颈静脉瓣功能不全是导致不同病理状况的一个因素。为了评估瓣膜功能不全,已开发出两种超声技术,它们基于截然不同的方法(直接多普勒评估与空气对比超声静脉造影[ACUV])。进行这项研究是为了比较这两种方法,以提高现有研究的可比性并提升未来研究的诊断准确性。在20名个体进行瓦尔萨尔瓦动作期间测定了40个瓣膜的功能。对于直接多普勒评估,根据最近确立的标准,基于多普勒记录评估瓣膜功能。当检测到基于空气的超声造影剂通过瓣膜反流时,诊断为ACUV瓣膜功能不全。两种方法均完成了对39个瓣膜的评估(一个瓣膜因相应静脉发育不全而被排除)。两种方法在检测率方面显示出高度一致性。根据多普勒标准被归类为功能不全的所有18个瓣膜在ACUV中也为功能不全。在21个被归类为功能正常(多普勒)的瓣膜中,有一个瓣膜因微泡的离散反流在ACUV中被评定为功能不全。然而,在将造影剂注入右肘正中静脉后,ACUV对左颈内静脉的评估不准确。只有考虑到这一点才能实现高检测率。这项研究表明,两种方法对颈内静脉瓣膜功能不全的检测率非常相似。然而,这种高度一致性需要对既定的ACUV方案进行修改。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验