To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures.
Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure.
Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs.
Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.
创建并测试从模拟肾支架手术记录中提取效率数据的方法。
进行任务分析并用于设计标准化测试方案。然后,五名经验丰富的血管造影师使用Simbionix AngioMentor血管造影模拟器进行了16次肾支架模拟。从多个有利位置捕获这些模拟的音频和视频记录。记录进行同步和汇编。然后从记录中提取一系列效率指标(手术时间、造影剂用量和工具使用情况)。还评估了这些个体指标的观察者内和观察者间变异性。将这些指标转换为成本并汇总,以确定手术片段或整个手术的固定成本和可变成本。
任务分析和预试验产生了适用于性能评估的标准化测试方案。任务分析还确定了七个检查点,将肾支架模拟分为六个片段。从记录中提取了这些不同片段的效率指标,显示出观察者内和观察者间的相关性极佳。对个体和汇总效率指标的分析表明,各片段之间以及不同血管造影师之间存在很大差异。当效率以总成本或可变成本表示时,这些差异仍然存在。
任务分析有助于方案制定和数据分析。效率指标很容易从模拟手术记录中提取。汇总指标并将手术分成片段揭示了一些潜在的见解,这些见解可能很容易被忽视,因为模拟器目前不尝试汇总指标,只提供来自整个手术的数据。数据表明,对模拟血管造影手术的分析将是评估介入放射学性能的一种有力方法。