Accurate determination of Se in biological samples, especially fish and shellfish, by hydride generation techniques has generally proven troublesome owing to the presence of organoselenium that cannot readily converted into inorganic selenium under usual oxidising conditions. Further improvements in the oxidation procedures are needed so as to obtain accurate concentration values when this type of samples is analyzed. Microwave-assisted wet digestion (MAWD) procedures of seafood based on HNO3 or the mixture HNO3/H2O2 and further thermal reduction of the Se(VI) formed to Se(IV) were evaluated. These procedures were as follows: (I) without H2O2 and without heating to dryness; (II) without H2O2 and with heating to dryness; (III) with H2O2 and without heating to dryness; (IV) with H2O2 and with heating to dryness. In general, low recoveries of selenium are obtained for several marine species (e.g., crustaceans and cephalopods), which may be ascribed to the presence of Se forms mainly associated with nonpolar proteins and lipids. Post-digestion UV irradiation proved very efficient since not only complete organoselenium decomposition was achieved but also the final step required for prereduction of Se(VI) into Se(IV) (i.e. heating at 90 degrees C for 30 min in 6M HCl) could be avoided. With the MAWD/UV procedure, the use of strong oxidising agents (persuphate, etc.) or acids (e.g. perchloric acid) which are typically applied prior to Se determination by hydride generation techniques is overcome, and as a result, sample pre-treatment is significantly simplified. The method was successfully validated against CRM DOLT-2 (dogfish liver), CRM DORM-2 (dogfish muscle) and CRM TORT-2 (lobster hepatopancreas). Automated ultrasonic slurry sampling with electrothermal atomic absorption spectrometry was also applied for comparison. Total Se contents in ten seafood samples were established. Se levels ranged from 0.7 to 2.9 microg g(-1).
通过氢化物发生技术准确测定生物样品,尤其是鱼类和贝类中的硒,通常已证明存在麻烦,因为存在有机硒,在通常的氧化条件下它不易转化为无机硒。当分析这类样品时,需要进一步改进氧化程序以获得准确的浓度值。评估了基于硝酸或硝酸/过氧化氢混合物的海鲜微波辅助湿消化(MAWD)程序,以及将形成的硒(VI)进一步热还原为硒(IV)的过程。这些程序如下:(I)不使用过氧化氢且不加热至干;(II)不使用过氧化氢且加热至干;(III)使用过氧化氢且不加热至干;(IV)使用过氧化氢且加热至干。一般来说,几种海洋物种(如甲壳类动物和头足类动物)的硒回收率较低,这可能归因于主要与非极性蛋白质和脂质相关的硒形式的存在。消化后紫外线照射证明非常有效,因为不仅实现了有机硒的完全分解,而且还可以避免将硒(VI)预还原为硒(IV)所需的最后一步(即在6M盐酸中于90℃加热30分钟)。使用MAWD/UV程序,克服了在通过氢化物发生技术测定硒之前通常使用的强氧化剂(过硫酸盐等)或酸(如高氯酸),结果显著简化了样品预处理。该方法已成功针对CRM DOLT - 2(角鲨肝)、CRM DORM - 2(角鲨肌肉)和CRM TORT - 2(龙虾肝胰腺)进行了验证。还应用了自动超声浆料进样与电热原子吸收光谱法进行比较。确定了十个海鲜样品中的总硒含量。硒含量范围为0.7至2.9微克/克(-1)。