Suppr超能文献

使用改良的水面采样器(WSS)测定多氯联苯(PCBs)的气相干沉降通量和传质系数(MTCs)。

The determination of gas phase dry deposition fluxes and mass transfer coefficients (MTCs) of polychlorinated biphenyls (PCBs) using a modified water surface sampler (WSS).

作者信息

Cindoruk S Siddik, Tasdemir Yücel

机构信息

Department of Environmental Engineering, Faculty of Engineering and Architecture, University of Uludag 16059 Gorukle, Bursa, Turkey.

出版信息

Sci Total Environ. 2007 Aug 1;381(1-3):212-21. doi: 10.1016/j.scitotenv.2007.03.011. Epub 2007 May 3.

Abstract

Gas phase PCB dry deposition and concentration samples were collected simultaneously between July 2004 and May 2005 at a suburban site in Bursa, Turkey. A modified water surface sampler (WSS) was employed to collect gas phase fluxes while a high-volume air sampler (HVAS) was used for concentration samples. The WSS was able to collect both particle and gas phase PCB deposition samples. The collected PCBs on water surface were captured by a filter and an XAD-2 resin column during water cycle. The average of gas phase PCB deposition flux, determined by analyzing the XAD-2 resin column, was 79.3+/-40.5 ng m(-2) d(-1) and its percentage in total (gas+particle) PCB flux was about 60. The average of gas phase PCB concentration measured concurrently with flux samples was 224.4+/-160.2 pg m(-3) and its ratio to the total (gas+particle) PCB concentration was 85%. This difference was likely due to the different deposition characteristics of gases and particulates. Dominant PCB homolog groups were 3-4 chlorobiphenyls (CBs) for both ambient air and gas phase deposition samples. Mass transfer coefficients (MTC, K(g)) for air-side were determined using gas phase flux and ambient air concentration values. The average overall K(g) ranged between 0.21 and 0.96 cm s(-1) with an average of 0.60+/-0.19 cm s(-1).

摘要

2004年7月至2005年5月期间,在土耳其布尔萨的一个郊区站点同时采集了气相多氯联苯(PCB)的干沉降和浓度样本。使用改良的水面采样器(WSS)采集气相通量样本,同时使用大容量空气采样器(HVAS)采集浓度样本。WSS能够采集颗粒相和气相的PCB沉降样本。在水循环过程中,水面上收集到的多氯联苯被过滤器和XAD - 2树脂柱捕获。通过分析XAD - 2树脂柱确定的气相PCB沉降通量平均值为79.3±40.5 ng m(-2) d(-1),其在总(气相 + 颗粒相)PCB通量中的百分比约为60%。与通量样本同时测量的气相PCB浓度平均值为224.4±160.2 pg m(-3),其与总(气相 + 颗粒相)PCB浓度的比值为85%。这种差异可能是由于气体和颗粒的不同沉积特性所致。对于环境空气和气相沉积样本,主要的多氯联苯同系物组均为三至四氯联苯(CBs)。利用气相通量和环境空气浓度值确定了空气侧的传质系数(MTC,K(g))。平均总K(g)在0.21至0.96 cm s(-1)之间,平均值为0.60±0.19 cm s(-1)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验