Suppr超能文献

Early postoperative myocardial morbidity in patients with coronary artery disease undergoing major non-cardiac surgery: correlation with perioperative ischaemia.

作者信息

Seegobin R D, Wilmshurst T H, Johnston J, Clewlow F, Murrills A, Seegobin A H, Goodland F, Wainwright C, Norman J, Conway N

机构信息

Department of Anaesthesia, University of Southampton.

出版信息

Can J Anaesth. 1991 Nov;38(8):1012-22. doi: 10.1007/BF03008620.

Abstract

As a part of a study assessing early postoperative myocardial morbidity in 50 patients with active coronary artery disease undergoing major non-cardiac surgery, the ECG was monitored continuously for 24 hr after the onset of anaesthesia, using a frequency modulated (FM) Holter monitor. Concurrent automated blood pressure and pulse were measured non-invasively at three-minute intervals during anaesthesia and subsequently at five-minute intervals. Thirty patients were monitored with two-site ECG recordings, from modified V1 and V5 (Group A). Twenty patients had seventeen-site ECG monitoring, multiplexing a four by four array of precordial electrodes onto one channel of the frequency modulated recorder (Group B). Tapes were analyzed for noise, supraventricular and ventricular dysrythmias, runs of tachy- and bradycardia, and ST segment changes. These data were correlated with serial standard 12-lead ECGs and CK-MB assay in the 72 hr after surgery. Seven tapes from Group A could not be analyzed. Change (greater than 1 mm) on ST monitoring from both Groups A (14/23), B (14/20), correlated with serial 12-lead ECG and/or CK-MB changes. The majority of first ST change 19/28 (70%) occurred after anaesthesia. In 14/28 (50%) ST change occurred during episodes of tachycardia and elevated blood pressure (greater than 20% above baseline). Nine patients (9/23) in Group A had no ST change; however, six had serial 12-lead ECG and/or CK-MB changes. Six patients (6/20) in Group B had no ST changes, and none of these patients had any change of serial 12-lead ECGs or CK-MB assay. No patient complained of chest pain during the Holter monitoring period. Continual monitoring of heart rate and blood pressure and accurate ST monitoring are essential to detect and treat perioperative myocardial ischemia. A multiple-lead precordial system is substantially more sensitive than traditional two-lead ECG holter monitoring in detecting myocardial ischaemia.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验