Suppr超能文献

Color Doppler findings in transplanted kidneys and remnant kidneys of donors 6 to 12 months after kidney transplantation.

作者信息

Khosroshahi H T, Tarzamni M K, Gojazadeh M, Bahluli A

机构信息

Kidney Transplant Center, Imam Hospital, Tabriz, Iran.

出版信息

Transplant Proc. 2007 May;39(4):816-8. doi: 10.1016/j.transproceed.2007.04.015.

Abstract

OBJECTIVES

Ultrasonography and color Doppler have been used extensively in the evaluation of transplanted kidney. The aim of this study was evaluation and comparison of color Doppler sonography findings in the remnant kidney of living donors and the transplanted kidney at 6 to 12 months after kidney transplantation.

METHODS

In a cross-sectional study we evaluated ultrasonographic (US) and color Doppler findings in 20 kidney allograft recipient and donors. Group 1 were unrelated and related kidney donors, and group 2, allograft recipients. Color Doppler US was performed by one sonologist on the remnant kidney of the living donor and the transplanted kidney of the recipient at 6 to 12 months after kidney donation and transplantation. We recorded, kidney size (including length and anteroposterior diameter), cortical thickness, resistive index (RI), and pulsatile index (PI). Statistical analysis was performed using SPSS 13 win (t test) for comparison of the results in donors and recipients. All data are presented as mean values +/- SD with P values less than .05 considered significant.

RESULTS

In group 1, mean age of kidney allograft recipients was 39.92 +/- 11.95 years with male-to-female ratio of 1/2. Mean length, width, and cortical thickness of the transplanted kidney were 120.15 +/- 11.95 mL, 53.65 +/- 7.50 mL, and 8.53 +/- 1.00 mL, respectively. Mean RI and PI were 0.60 +/- 0.08 and 1.02 +/- 0.23, respectively. Mean serum creatinine was 1.23 +/- 0.24 mg/dL. Mean duration of renal transplantation was 7.27 +/- 1.10 months. In group 2, mean age of recipients was 25.63 +/- 3.50 years with male-to-female ratio of 1/10. Mean length, anteroposterior diameter, and cortical thickness were 120.77 +/- 9.28 mL, 53.36 +/- 4.52 mL, and 9.04 +/- 1.27 mL, respectively. Mean RI and PI were 0.60 +/- 0.02 and 1.07 +/- 0.13, respectively. There was no significant difference in the length, anteroposterior diameter, cortical thickness, RI, and PI of donors and transplanted kidneys at 6 to 12 months after transplantation (P>.05). There was a significant increase in both donor and recipient kidney size at 6 to 12 months after transplantation (P<.05).

CONCLUSION

It seems that renal US and Doppler parameters remain stable in the recipient and donor at least upon short-term evaluation. Long-term study with more patients is recommended.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验