Suppr超能文献

外翻-内翻方向对股骨头表面置换中负荷传递影响的研究:多股骨有限元分析

Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.

作者信息

Radcliffe I A J, Taylor M

机构信息

Bioengineering Science Research Group, University of Southampton, Highfield, Southampton, SO17 1BJ, UK.

出版信息

Clin Biomech (Bristol). 2007 Aug;22(7):780-6. doi: 10.1016/j.clinbiomech.2007.03.011. Epub 2007 Jun 4.

Abstract

BACKGROUND

Femoral head resurfacing is a popular procedure for younger active hip replacement patients. Whilst the current generation of metal-on-metal resurfacing arthroplasties appear to have cured the osteolysis problems that plagued earlier resurfacing implants, fracture of the femoral head and aseptic loosening are still factors of concern in its survivorship. Several studies have shown a tendency towards failure in resurfaced femurs where the implant has been set at a varus angle. This work aims to investigate the influence of varus-valgus orientation on load transfer within the resurfaced proximal femur.

METHODS

This study uses Computer Tomography based finite element analysis to determine the effect of implant orientation on load transfer in the proximal femur with respect to the intact femur. A group of 16 femurs were studied to take into account inter-patient variation; four models were produced for each femur, one of the intact femur, one resurfaced with the implant set inline with the femoral neck and one each representing varus and valgus implant alignment.

FINDINGS

Results showed the valgus aligned resurfaced femur to produce strain patterns more akin to the intact femur. As the implant's angle to the femoral shaft increases from varus to valgus the strains in the superior femoral neck are reduced while those in the inferior neck are increased.

INTERPRETATION

The study concluded that valgus alignment of the resurfacing arthroplasty is preferential to varus alignment; as it induces a more physiological strain pattern and reduces the risk of femoral neck fracture. These findings are in line with clinical experience, which has shown an increase of failure with varus implanted prostheses.

摘要

背景

对于年轻且活跃的髋关节置换患者,股骨头表面置换是一种常用的手术方法。尽管当前一代的金属对金属表面置换关节成形术似乎已解决了困扰早期表面置换植入物的骨溶解问题,但股骨头骨折和无菌性松动仍是影响其长期使用的因素。多项研究表明,当植入物以内翻角度置入时,表面置换的股骨有失败的倾向。本研究旨在探讨内翻-外翻方向对表面置换的股骨近端负荷传递的影响。

方法

本研究采用基于计算机断层扫描的有限元分析,以确定植入物方向对股骨近端相对于完整股骨的负荷传递的影响。研究了一组16个股骨,以考虑患者间的差异;为每个股骨制作了四个模型,一个是完整股骨模型,一个是植入物与股骨颈对齐的表面置换模型,另外两个分别代表内翻和外翻植入物对齐。

结果

结果显示,外翻对齐的表面置换股骨产生的应变模式更类似于完整股骨。随着植入物与股骨干的角度从内翻增加到外翻,股骨颈上部的应变减小,而下部颈的应变增加。

解读

该研究得出结论,表面置换关节成形术的外翻对齐优于内翻对齐;因为它能诱导更符合生理的应变模式,并降低股骨颈骨折的风险。这些发现与临床经验一致,临床经验表明内翻植入假体的失败率增加。