多巴酚丁胺与腺苷负荷实时心肌灌注超声心动图检测冠状动脉疾病的头对头比较。

Head-to-head comparison of dobutamine and adenosine stress real-time myocardial perfusion echocardiography for the detection of coronary artery disease.

作者信息

Kowatsch Ingrid, Tsutsui Jeane M, Osório Altamiro F F, Uchida Augusto H, Machiori Gilberto G A, Lopes Marden L, César Luiz A M, Ramires José Antônio F, Mathias Wilson

机构信息

Heart Institute (InCor), University of São Paulo Medical School, São Paulo, Brazil.

出版信息

J Am Soc Echocardiogr. 2007 Sep;20(9):1109-17. doi: 10.1016/j.echo.2007.02.008. Epub 2007 Jun 12.

Abstract

We sought to determine the value of dobutamine versus adenosine real-time myocardial perfusion (MP) echocardiography for detecting coronary artery disease and the value of quantitative analysis of MP over electrocardiography, wall motion, and qualitative MP. We studied 54 patients by real-time MP echocardiography and coronary angiography. Replenishment velocity (beta) and an index of myocardial blood flow (A(n)xbeta) were derived from quantitative MP. During dobutamine stress, beta (1.7 +/- 0.7 vs 2.7 +/- 1.2; P < .001) and A(n)xbeta (2.2 +/- 1.0 vs 3.5 +/- 1.6; P < .001) reserves were lower in patients with coronary artery disease. The same was observed with adenosine for beta (1.7 +/- 0.8 vs 2.5 +/- 1.1; P < .001) and A(n)xbeta (1.9 +/- 0.7 vs 3.2 +/- 1.4; P < .001) reserves. Accuracy of electrocardiography, wall motion, qualitative MP, and quantitative MP were 61%, 76%, 76%, and 80% for dobutamine and 70%, 70%, 76%, and 80% for adenosine, respectively. Quantitative MP had incremental diagnostic value over other variables during dobutamine (chi(2) 23.7-38.4; P < .001) and adenosine (chi(2) 26.7-59.4; P < .001). In conclusion, dobutamine and adenosine real-time MP echocardiography hold similar accuracy for detecting coronary artery disease. Quantitative MP provides incremental diagnostic information over other variables.

摘要

我们试图确定多巴酚丁胺与腺苷实时心肌灌注(MP)超声心动图在检测冠状动脉疾病方面的价值,以及MP定量分析相对于心电图、壁运动和定性MP的价值。我们通过实时MP超声心动图和冠状动脉造影研究了54例患者。从定量MP中得出再充盈速度(β)和心肌血流指数(A(n)×β)。在多巴酚丁胺负荷试验期间,冠状动脉疾病患者的β储备(1.7±0.7对2.7±1.2;P<.001)和A(n)×β储备(2.2±1.0对3.5±1.6;P<.001)较低。腺苷负荷试验时β储备(1.7±0.8对2.5±1.1;P<.001)和A(n)×β储备(1.9±0.7对3.2±1.4;P<.001)也观察到同样情况。多巴酚丁胺试验中,心电图、壁运动、定性MP和定量MP的准确性分别为61%、76%、76%和80%,腺苷试验中分别为70%、70%、76%和80%。在多巴酚丁胺(χ² 23.7 - 38.4;P<.001)和腺苷(χ² 26.7 - 59.4;P<.001)试验期间,定量MP相对于其他变量具有增量诊断价值。总之,多巴酚丁胺和腺苷实时MP超声心动图在检测冠状动脉疾病方面具有相似的准确性。定量MP比其他变量提供了更多的诊断信息。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验