Suppr超能文献

钆布醇心肌首过灌注成像:并行成像算法对图像质量和信号行为的影响。

Myocardial first pass perfusion imaging with gadobutrol: impact of parallel imaging algorithms on image quality and signal behavior.

作者信息

Theisen Daniel, Wintersperger Bernd J, Huber Armin, Dietrich Olaf, Reiser Maximilian F, Schönberg Stefan O

机构信息

Department of Clinical Radiology, Campus Grosshadern, Ludwig-Maximilians-University, Munich, Germany.

出版信息

Invest Radiol. 2007 Jul;42(7):522-8. doi: 10.1097/RLI.0b013e3180383572.

Abstract

OBJECTIVE

To implement parallel imaging algorithms in fast gradient recalled echo sequences for myocardial perfusion imaging and evaluate image quality, signal-to-noise ratio (SNR), contrast-enhancement ratio (CER), and semiquantitative perfusion parameters.

MATERIALS AND METHODS

In 20 volunteers, myocardial perfusion imaging with gadobutrol was performed at rest using an accelerated TurboFLASH sequence (TR 2.3 milliseconds, TE 0.93 milliseconds, flip angle [FA] 15 degrees) with GRAPPA, R=2. A nonaccelerated TurboFLASH sequence with similar scan parameters served as standard of reference. Artifacts were assessed qualitatively. SNR, CER, and CNR were calculated and semiquantitative perfusion parameters were determined from fitted SI-time curves.

RESULTS

Phantom measurements yielded significant higher SNR for nonaccelerated images (P<0.001). CER was equal; differences in CNR were statistically nonsignificant. The evaluation of semiquantitative perfusion parameters yielded significantly higher peak signal intensities in nonaccelerated images (P<0.001). Differences in maximum upslope were statistically nonsignificant. A qualitative examination of all images for artifacts by 2 board-certified radiologists yielded a significant reduction in dark rim artifacts with GRAPPA, R=2 (P<0.001).

CONCLUSIONS

The application of GRAPPA with an acceleration factor of R=2 leads to a significant reduction of dark rim artifacts in fast gradient recalled echo sequences.

摘要

目的

在快速梯度回波序列中实施并行成像算法用于心肌灌注成像,并评估图像质量、信噪比(SNR)、对比增强率(CER)和半定量灌注参数。

材料与方法

对20名志愿者,使用具有GRAPPA、加速因子R = 2的加速TurboFLASH序列(重复时间[TR] 2.3毫秒,回波时间[TE] 0.93毫秒,翻转角[FA] 15°)静息状态下进行钆布醇心肌灌注成像。具有相似扫描参数的非加速TurboFLASH序列作为参考标准。对伪影进行定性评估。计算SNR、CER和对比噪声比(CNR),并从拟合的信号强度-时间曲线确定半定量灌注参数。

结果

模体测量显示非加速图像的SNR显著更高(P < 0.001)。CER相等;CNR差异无统计学意义。半定量灌注参数评估显示非加速图像的峰值信号强度显著更高(P < 0.001)。最大上升斜率差异无统计学意义。2名具有专业资格认证的放射科医生对所有图像的伪影进行定性检查,结果显示GRAPPA、R = 2时暗边伪影显著减少(P < 0.001)。

结论

应用加速因子R = 2的GRAPPA可显著减少快速梯度回波序列中的暗边伪影。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验