Suppr超能文献

每周进行八次扫描后,未检测到体内微型计算机断层扫描辐射对Wistar大鼠胫骨近端的结构参数和骨髓细胞有影响。

No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scans.

作者信息

Brouwers Julienne E M, van Rietbergen Bert, Huiskes Rik

机构信息

Eindhoven University of Technology, W-hoog 4.128, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.

出版信息

J Orthop Res. 2007 Oct;25(10):1325-32. doi: 10.1002/jor.20439.

Abstract

Recently developed in vivo animal high-resolution micro-CT scanners offer the possibility to monitor longitudinal changes in bone microstructure of small rodents, but may impose high radiation doses that could damage bone tissue. The goal of this study was to determine the effects on the bone of 8 weeks of in vivo scanning of the proximal tibia in female Wistar rats. Eight weekly CT scans were made of the right proximal tibia of nine female, 30-week-old, retired-breeder, Wistar rats. Two weeks after the last weekly scan, a final scan was made. The left leg was only scanned during first and final measurements and served as a control. A two-way ANOVA with repeated measures was performed on the first and last measurements of left and right tibiae for six bone structural parameters. Bone marrow cells were flushed out and tested for cell viability. No significant difference was found between left and right for any of the bone structural parameters (p > 0.05). Structure model index and trabecular separation significantly changed as a result of aging, while none of the other parameters did. No significant difference was found between left and right in absolute and percentage number of cell viability. We did not find any indication that the applied scanning regime, in combination with the particular settings used, would affect the results of in vivo bone structural measurements in long-term studies using aged, female Wistar rats. However, careful consideration should be made when determining the number of scans, particularly when a different experimental design is used.

摘要

最近开发的活体动物高分辨率微型CT扫描仪提供了监测小型啮齿动物骨骼微观结构纵向变化的可能性,但可能会施加高辐射剂量,从而损害骨组织。本研究的目的是确定对雌性Wistar大鼠胫骨近端进行8周活体扫描对骨骼的影响。对9只30周龄、已退休繁殖的雌性Wistar大鼠的右胫骨近端进行了8次每周一次的CT扫描。在最后一次每周扫描两周后,进行了最后一次扫描。左腿仅在第一次和最后一次测量时进行扫描,并作为对照。对左右胫骨的第一次和最后一次测量的六个骨结构参数进行了重复测量的双向方差分析。冲洗出骨髓细胞并测试细胞活力。任何骨结构参数在左右之间均未发现显著差异(p>0.05)。结构模型指数和小梁间距因衰老而显著变化,而其他参数均未变化。细胞活力的绝对数量和百分比在左右之间未发现显著差异。我们没有发现任何迹象表明,在使用老龄雌性Wistar大鼠的长期研究中,所应用的扫描方案与所使用的特定设置相结合会影响活体骨结构测量的结果。然而,在确定扫描次数时应谨慎考虑,特别是当使用不同的实验设计时。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验