Pourreza N, Elhami Sh
Department of Chemistry, College of Science, Shahid Chamran University, Ahvaz, Iran.
Anal Chim Acta. 2007 Jul 16;596(1):62-5. doi: 10.1016/j.aca.2007.05.042. Epub 2007 May 29.
A novel and sensitive cloud point extraction procedure for the determination of trace amounts of malachite green by spectrophotometry was developed. Malachite green was extracted at pH 2.5 mediated by micelles of nonionic surfactant Triton X-100. The extracted surfactant-rich phase was diluted with ethanol and its absorbance was measured at 630 nm. The effect of different variables such as pH, Triton X-100 concentration, cloud point temperature and time and diverse ions was investigated and optimum conditions were established. The calibration graph was linear in the range of 4-500 ng mL(-1) of malachite green in the initial solution with r=0.9996 (n=10). Detection limit based on three times the standard deviation of the blank (3S(b)) was 1.2 ng mL(-1) and the relative standard deviation (R.S.D.) for 20 and 300 ng mL(-1) of malachite green was 1.48 and 1.13% (n=8), respectively. The method was applied to the determination of malachite green in different fish farming and river water samples.
开发了一种新颖且灵敏的浊点萃取法,用于通过分光光度法测定微量孔雀石绿。在非离子表面活性剂Triton X - 100的胶束介导下,于pH 2.5时萃取孔雀石绿。萃取得到的富含表面活性剂的相用乙醇稀释,并在630 nm处测量其吸光度。研究了不同变量如pH、Triton X - 100浓度、浊点温度和时间以及各种离子的影响,并确定了最佳条件。初始溶液中孔雀石绿浓度在4 - 500 ng mL(-1)范围内校准曲线呈线性,r = 0.9996 (n = 10)。基于空白三倍标准偏差(3S(b))的检测限为1.2 ng mL(-1),20和300 ng mL(-1)孔雀石绿的相对标准偏差(R.S.D.)分别为1.48%和1.13% (n = 8)。该方法应用于不同养鱼场和河水样品中孔雀石绿的测定。