Viñas Pilar, Campillo Natalia, Aguinaga Nerea, Pérez-Cánovas Eva, Hernández-Córdoba Manuel
Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30071, Murcia, Spain.
J Chromatogr A. 2007 Sep 14;1164(1-2):10-7. doi: 10.1016/j.chroma.2007.06.056. Epub 2007 Jul 1.
A sensitive and solvent-free procedure for the determination of 11 polycyclic aromatic hydrocarbons in tea infusions using headspace solid-phase microextraction coupled to liquid chromatography with fluorimetric detection is described. A medium polarity polydimethylsiloxane-divinylbenzene 60 microm fiber was found to be suitable for extraction at 90 degrees C and with an extraction time of 60 min under continuous stirring. Desorption was carried out using the static mode for 5 min. Under the optimized conditions, when 1.75 g of tea sample were extracted with boiling water, the precision ranged from 4 to 16% (RSD) and detection limits were between 4 and 145 ngL(-1), depending on the compound. The reliability of the procedure was corroborated by means of GC-MS. The results obtained for a standard reference material were within the range indicated by the supplier.