Tanne K, Matsubara S, Shibaguchi T, Sakuda M
Department of Orthodontics, Osaka University Faculty of Dentistry, Japan.
Angle Orthod. 1991 Winter;61(4):285-90; discussion 291-2. doi: 10.1043/0003-3219(1991)061<0285:WFFCBD>2.0.CO;2.
The present study was designed to investigate the nature of friction between orthodontic wire and various ceramic brackets. The amount of tooth movement with metal and ceramic brackets was measured, and the wire surfaces were examined microscopically immediately after artificial tooth movement. The amount of tooth movement produced by the ceramic brackets was significantly less than that produced by metal bracket. The wire surfaces were scratched more obviously by ceramic brackets than by metal bracket. Slot surfaces and edges of the ceramic brackets were substantially more porous and rougher than those surfaces of the metal bracket. These material differences between metal and ceramic brackets significantly affect the efficiency of orthodontic tooth movement.
本研究旨在探究正畸弓丝与各种陶瓷托槽之间的摩擦力性质。测量了使用金属托槽和陶瓷托槽时牙齿移动的量,并在人工牙齿移动后立即对弓丝表面进行微观检查。陶瓷托槽产生的牙齿移动量明显少于金属托槽产生的牙齿移动量。与金属托槽相比,陶瓷托槽对弓丝表面的刮擦更明显。陶瓷托槽的槽沟表面和边缘比金属托槽的表面孔隙更多且更粗糙。金属托槽和陶瓷托槽之间的这些材料差异显著影响正畸牙齿移动的效率。