Hernández N López, Escrivá A García, Jordà J M Moltó
Sección de Neurología, Hospital General Universitario de Elche, Alicante, Spain.
Neurologia. 2007 Oct;22(8):507-10.
Transtemporal insonation by means of transcranial color-coded duplex sonography (TCDS) with low frequency probes (2-2.5 MHz) makes it possible to not only evaluate the blood vessels of the circle of Willis but also of brain parenchymal structures. A reduced number of studies, none of them in our area, have reported its usefulness for the evaluation of the ventricular system in adults. Aim. To evaluate ability of the transcranial duplex to measure the third ventricle diameter in a sample of patients with different neurological illnesses.
Patients of all ages admitted to our neurology ward and whose diagnostic procedure included a brain magnetic resonance (MRI) were recruited. The largest third ventricle diameter was measured with both the TCDS and MRI in axial planes. We report the results observed with both techniques and the lineal correlation between both of them.
We included 30 patients with mean age 48.5 years and 66.6% females. The third ventricle diameter (average +/- standard deviation) was 3.97 +/- 2.58 mm as measured with TCDS and 3.70 +/- 2.27 mm on MRI. Linear correlation between the values observed was high (r=0.85).
Transcranial duplex is a cheap, safe and easy to perform technique. It has similar results in comparison with those obtained with the MRI when the third ventricle size is measured.
使用低频探头(2 - 2.5兆赫兹)通过经颅彩色编码双功能超声(TCDS)进行颞部超声检查,不仅可以评估 Willis 环的血管,还能评估脑实质结构。较少的研究报道了其在成人脑室系统评估中的作用,且我们所在地区尚无相关研究。目的:评估经颅双功能超声在不同神经系统疾病患者样本中测量第三脑室直径的能力。
招募入住我们神经内科病房且诊断程序包括脑部磁共振成像(MRI)的各年龄段患者。在轴向平面上使用TCDS和MRI测量第三脑室的最大直径。我们报告两种技术观察到的结果以及两者之间的线性相关性。
我们纳入了30例患者,平均年龄48.5岁,女性占66.6%。用TCDS测量的第三脑室直径(平均值±标准差)为3.97±2.58毫米,MRI测量值为3.70±2.27毫米。观察值之间的线性相关性很高(r = 0.85)。
经颅双功能超声是一种廉价、安全且易于操作的技术。在测量第三脑室大小时,与MRI获得的结果相似。