Suppr超能文献

用于在类似GSM900和UMTS暴露期间进行脑电图记录的人体激发研究的新型头部暴露系统。

New head exposure system for use in human provocation studies with EEG recording during GSM900- and UMTS-like exposure.

作者信息

Schmid Gernot, Cecil Stefan, Goger Christoph, Trimmel Michael, Kuster Niels, Molla-Djafari Hamid

机构信息

Austrian Research Centers GmbH-ARC, Seibersdorf, Austria.

出版信息

Bioelectromagnetics. 2007 Dec;28(8):636-47. doi: 10.1002/bem.20340.

Abstract

A new head exposure system for double blinded human provocation studies, which requires EEG recording during exposure with GSM900- and UMTS-like signals has been developed and dosimetrically evaluated. The system uses planar patch antennas fixed at 65 mm distance from the subject's head by a special headset, which provides minimum impairment of the test subjects and ensures an almost constant position of the antennas with respect to the head, even in case of head movements. Compared to exposure concepts operating small antennas in close proximity to the head, the concept of planar antennas at a certain distance from the head produces a much more homogeneous SAR distribution in the temporal and parietal lobe of the brain. At the same time the resulting uncertainty of exposure due to variations in head size, variations of the dielectric properties of tissues and unavoidable small changes of the antenna's position with respect to the head, is reduced to the order of approximately 3 dB, which is a significant improvement to comparable head exposure systems reported in literature in the past. To avoid electromagnetic interference on the EEG recording caused by the incident RF-field an appropriate double-shielded filter circuit has been developed. Furthermore, the effect of the presence of the sintered Ag/AgCl EEG electrodes and electrode wires on the SAR distribution inside the head has been investigated and was found to be minimal if the electrode wires are arranged orthogonal to the incident electric field vector. EEG electrode arrangement parallel to the incident field vector, however, might cause drastic changes in the SAR distribution inside the head.

摘要

一种用于双盲人体激发研究的新型头部暴露系统已被开发出来,并进行了剂量学评估,该系统在暴露于类似GSM900和UMTS的信号期间需要进行脑电图记录。该系统使用平面贴片天线,通过特殊的头戴式装置固定在距受试者头部65毫米的距离处,这种装置对测试对象的损害最小,并确保天线相对于头部的位置几乎恒定,即使在头部移动的情况下也是如此。与在头部附近操作小天线的暴露概念相比,在距头部一定距离处使用平面天线的概念在大脑颞叶和顶叶中产生的比吸收率(SAR)分布要均匀得多。同时,由于头部尺寸变化、组织介电特性变化以及天线相对于头部位置不可避免的微小变化而导致的暴露不确定性降低到大约3 dB的量级,这相对于过去文献中报道的类似头部暴露系统有了显著改进。为了避免入射射频场对脑电图记录产生电磁干扰,已开发出一种合适的双屏蔽滤波电路。此外,还研究了烧结Ag/AgCl脑电图电极和电极线的存在对头部内部SAR分布的影响,发现如果电极线与入射电场矢量正交排列,则影响最小。然而,脑电图电极与入射场矢量平行排列可能会导致头部内部SAR分布发生剧烈变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验