Nandrolone (17beta-hydroxy-4-estren-3-one, NAD) is an endogenous steroid hormone; thus, the detection of its metabolites is not conclusive of NAD doping in racehorses. NAD doping control in male horses is based on the threshold, namely, the concentration ratio of 5alpha-estran-3beta,17alpha-diol (ETA) to 5(10)-estren-3beta,17alpha-diol (ETE). The ETA/ETE ratio of 1/1 was determined based on statistical data of authentic horses in International Federation of Horseracing Authorities. To individuals with complex metabolic disorders, however, such a threshold might not be applicable. The aim of this study was to establish an analytical method that discriminates endogenous steroids from exogenous ones in horse urine after NAD administration using gas chromatography/combustion/carbon isotope ratio mass spectrometry (GC/C/IRMS). Urine was sampled from NAD-administered and authentic horses. Ten millilitres of urine was hydrolyzed and subjected to liquid-liquid extraction and solid phase extraction. The residue of the extracts purified by HPLC was derivatized by acetylation. As a result of measurement of the (13)C/(12)C ratio (delta(13)C) by GC/C/IRMS, the delta(13)C values of ETA for NAD-administered and authentic horses were -32.20+/-0.35 per thousand and -27.85+/-0.75 per thousand (n=60), respectively. The detection limit of ETA in this GC/C/IRMS analysis was approximately 25 ng/ml. This study indicates that the measurement of delta(13)C by GC/C/IRMS enables us to discriminate exogenous ETA derived from NAD administration from endogenous ETA, proving that GC/C/IRMS is a useful technique to complement the ETA/ETE ratio.

摘要

诺龙(17β-羟基-4-雌甾烯-3-酮,NAD)是一种内源性甾体激素;因此,检测其代谢产物并不能确凿证明赛马存在诺龙兴奋剂问题。雄性马匹的诺龙兴奋剂检测基于阈值,即5α-雌甾烷-3β,17α-二醇(ETA)与5(10)-雌甾烯-3β,17α-二醇(ETE)的浓度比。ETA/ETE比值1/1是根据国际赛马管理机构真实马匹的统计数据确定的。然而,对于患有复杂代谢紊乱的个体,这样的阈值可能并不适用。本研究的目的是建立一种分析方法,使用气相色谱/燃烧/碳同位素比值质谱法(GC/C/IRMS),在给马匹注射诺龙后区分马尿中的内源性甾体和外源性甾体。从注射诺龙的马匹和正常马匹采集尿液。取10毫升尿液进行水解,然后进行液液萃取和固相萃取。通过高效液相色谱纯化的提取物残渣经乙酰化衍生化。通过GC/C/IRMS测量(13)C/(12)C比值(δ13C)的结果显示,注射诺龙的马匹和正常马匹的ETA的δ13C值分别为-32.20±0.35‰和-27.85±0.75‰(n = 60)。在这种GC/C/IRMS分析中,ETA的检测限约为25纳克/毫升。本研究表明,通过GC/C/IRMS测量δ13C能够使我们区分注射诺龙产生的外源性ETA和内源性ETA,证明GC/C/IRMS是一种补充ETA/ETE比值的有用技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验