Suppr超能文献

8-氨基-N-(2-羟基亚苄基)萘胺作为中性离子载体在镧离子选择性传感器构建中的应用。

Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor.

作者信息

Ganjali M R, Norouzi P, Alizadeh T, Adib M

机构信息

Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran.

出版信息

Anal Chim Acta. 2006 Aug 25;576(2):275-82. doi: 10.1016/j.aca.2006.06.037. Epub 2006 Jun 29.

Abstract

In this work, a novel La(III) membrane sensor based on 8-amino-N-(2-hydroxybenzylidene)naphthylamine (AIP) is presented. This electrode reveals good selectivity for La(3+) over a wide variety of lanthanides metal ions. Theoretical calculations and conductance study of AIP to lanthanum and some other metal ions were carried out and confirmed selectivity toward La(III) ions. The electrode comprises 7% AIP, 30% PVC, 61% NPOE and 2% KTpClPB. The sensor displays a linear dynamic range between 1.0 x 10(-7) and 1.0 x 10(-1) M, with a nice Nernstian slope of 20.3+/-0.3 mV per decade and a detection limit of 8.0 x 10(-8) M. The potentiometric response is independent of pH in the range of 4.0-9.0. The proposed sensor posses the advantage of short response time, and especially, very good selectivity towards a large number of cations, such as Sm(III), Ce(III, Pr(III), Yb(III) and Hg(II), low detection limit and wide linear dynamic range in comparison with former ones. The electrode can be used for at least seven weeks without any considerable divergence in the potentials. It was used as an indicator electrode in the potentiometric titration of La(III) ions with EDTA. The sensor was applied to the determination of La(III) ions concentration in binary mixtures. It was also applied for the determination of fluoride ions in mouth wash preparations.

摘要

在这项工作中,提出了一种基于8-氨基-N-(2-羟基亚苄基)萘胺(AIP)的新型镧(III)膜传感器。该电极对镧(3+)在多种镧系金属离子中表现出良好的选择性。进行了AIP对镧和其他一些金属离子的理论计算和电导研究,证实了对镧(III)离子的选择性。该电极由7%AIP、30%聚氯乙烯(PVC)、61%硝基苯辛醚(NPOE)和2%四苯硼钾(KTpClPB)组成。该传感器的线性动态范围为1.0×10(-7)至1.0×10(-1)M,每十年具有20.3±0.3mV的良好能斯特斜率,检测限为8.0×10(-8)M。电位响应在4.0 - 9.0的pH范围内与pH无关。所提出的传感器具有响应时间短的优点,特别是对大量阳离子,如钐(III)、铈(III)、镨(III)、镱(III)和汞(II)具有非常好的选择性,与以前的传感器相比检测限低且线性动态范围宽。该电极可使用至少七周,电位没有任何明显偏差。它被用作指示电极,用于用乙二胺四乙酸(EDTA)电位滴定镧(III)离子。该传感器应用于二元混合物中镧(III)离子浓度的测定。它还被应用于漱口水制剂中氟离子的测定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验