Cheng Shan, Qiu Feng, Huang Jia, He Junqi
Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Capital Medical University, No.10 Xitoutiao, You An Men, Beijing 100069, China.
J Chromatogr Sci. 2007 Aug;45(7):409-14. doi: 10.1093/chromsci/45.7.409.
A simple and rapid high-performance liquid chromatographic method with UV detection is developed and validated to determine the concentration of voriconazole in rat and beagle dog plasma. After protein precipitation using acetonitrile, the supernatant solution is chromatographed on a Diamonsil C(18) column (250 x 4.6-mm i.d., 5 microm). The mobile phase used is a combination of acetonitrile-water-acetic acid (55:45:0.25, v/v/v) with a pH of 4.0. Detection is achieved by a UV detector monitored at a wavelength of 256 nm. The matrix calibration curves are obtained both in the concentration range of 0.10-50.0 microg/mL in rat and beagle dog plasma, with the lower limit of quantitation of 0.10 microg/mL. The intra- and inter-assay precisions in terms of % relative standard deviation are lower than 8.6% and 6.0% in rat and beagle dog plasma, respectively. The accuracy in terms of % relative error ranged from -0.5% to 8.0% and -0.5% to 6.0% in rat and beagle dog plasma, respectively. This validated method is successfully applied to determine the concentration of voriconazole in plasma after intravenous administration of 36 mg/kg voriconazole to rats and 10 mg/kg voriconazole to beagle dogs, respectively.
建立并验证了一种简单快速的带紫外检测的高效液相色谱法,用于测定大鼠和比格犬血浆中伏立康唑的浓度。用乙腈进行蛋白沉淀后,上清液在Diamonsil C(18)柱(内径250×4.6 mm,5μm)上进行色谱分析。所用流动相为乙腈 - 水 - 乙酸(55:45:0.25,v/v/v),pH为4.0。通过在256 nm波长下监测的紫外检测器进行检测。在大鼠和比格犬血浆中,基质校准曲线在0.10 - 50.0μg/mL浓度范围内获得,定量下限为0.10μg/mL。大鼠和比格犬血浆中,批内和批间精密度的相对标准偏差分别低于8.6%和6.0%。大鼠和比格犬血浆中,相对误差的准确度分别在 -0.5%至8.0%和 -0.5%至6.0%范围内。该验证方法成功应用于分别给大鼠静脉注射36 mg/kg伏立康唑和给比格犬静脉注射10 mg/kg伏立康唑后血浆中伏立康唑浓度的测定。