• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The effects of common matrices for assay standards on performance of 'ultra sensitive' immunometric assays for TSH. Report of a joint WHO/IFCC collaborative study.

作者信息

Gaines-Das R E, Brettschneider H, Bristow A F

机构信息

WHO International Laboratory for Biological Standards, National Institute for Biological Standards and Control, South Mimms, Potters Bar, Herts, UK.

出版信息

Clin Chim Acta. 1991 Dec 16;203(2-3):S5-15. doi: 10.1016/0009-8981(91)90325-7.

DOI:10.1016/0009-8981(91)90325-7
PMID:1777974
Abstract

This report describes the results of a collaborative study organized by a joint working group of IFCC and WHO and involving nine manufacturers of TSH immunometric assay kits. The study was designed to determine whether a calibrator with a common matrix gives better between-laboratory agreement for calibration of serum samples than the various kit calibrators, and to assess various materials for their suitability for use as common matrices. Kit calibrators or calibrators consisting of the IRP for TSH made up in two common matrices, (1) serum from patients with untreated thyrotoxicosis or (2) serum taken from subjects treated with suppressive doses of triiodothyronine, gave similar results for the between-laboratory variation of estimates of TSH concentration for a range of serum samples. Dose-response curves for the two calibrators in 'common' matrices were similar to one another and to those for the kit calibrator. However, the occurrence of non-specific serum effects is shown by the comparison of results for these calibrators with results for calibrators made up in a third common matrix, serum treated with wheat germ lectin. Dose-response curves for this calibrator were dissimilar to those for the other calibrators and between-laboratory variation for estimates in terms of this latter calibrator showed a substantial increase. Moreover, although the between-laboratory variances for estimates of the TSH concentration in terms of each of these calibrators (except those made up in serum treated with in the wheat germ lectin) were similar for any one sample from five hyperthyroid patients, the variances were not consistent between samples, even for samples with similar mean TSH concentrations. These results suggest that a major factor in the between-laboratory variation, especially in the region near 'zero dose', is sample-related, and is caused by particular samples interacting differently with different assay systems. In general, it would appear that for the well controlled 'ultra-sensitive' TSH immunometric assay kits, included in this study, between-laboratory agreement of estimates of the TSH concentration in serum samples is not likely to be substantially improved by use of a common matrix for the standards.

摘要

相似文献

1
The effects of common matrices for assay standards on performance of 'ultra sensitive' immunometric assays for TSH. Report of a joint WHO/IFCC collaborative study.
Clin Chim Acta. 1991 Dec 16;203(2-3):S5-15. doi: 10.1016/0009-8981(91)90325-7.
2
The effects of common matrices for assay standards on performance of 'ultra sensitive' immunometric assays for TSH: Report of a joint WHO/IFCC collaborative study.用于促甲状腺激素检测标准品的常见基质对“超灵敏”免疫分析性能的影响:世界卫生组织/国际临床化学和检验医学联合会联合协作研究报告
J Automat Chem. 1991;13(5):209-15. doi: 10.1155/S1463924691000354.
3
The effects of common matrices for assay standards on performance of "ultra sensitive" immunometric assays for TSH. Report of a joint WHO/IFCC collaborative study.常用分析标准品基质对促甲状腺激素“超敏”免疫分析性能的影响。世界卫生组织/国际临床化学和检验医学联合会联合协作研究报告
Ann Biol Clin (Paris). 1991;49(10):522-7.
4
An evaluation of six solid-phase thyrotropin (TSH) kits.六种固相促甲状腺激素(TSH)试剂盒的评估。
J Clin Chem Clin Biochem. 1985 Aug;23(8):461-71. doi: 10.1515/cclm.1985.23.8.461.
5
Two sensitive immunometric assays for serum thyroid stimulating hormone evaluated.评估了两种用于血清促甲状腺激素的灵敏免疫测定法。
Ann Clin Lab Sci. 1998 Mar-Apr;28(2):88-98.
6
Interassay variability of immunometric methods for thyrotropin in an external quality assessment survey: evidence that functional sensitivity is not always adequate for clinical decisions.促甲状腺素免疫测定方法在外部质量评估调查中的批间变异:功能灵敏度并不总是足以用于临床决策的证据。
Clin Chem. 1992 Jul;38(7):1345-9.
7
The nature of calibrators in immunoassays: are they commutable with test samples? Must they be?免疫测定中校准品的本质:它们与测试样品具有互换性吗?有这个必要吗?
Scand J Clin Lab Invest Suppl. 1991;205:47-54. doi: 10.3109/00365519109104601.
8
Feasibility study of new calibrators for thyroid-stimulating hormone (TSH) immunoprocedures based on remodeling of recombinant TSH to mimic glycoforms circulating in patients with thyroid disorders.基于重组促甲状腺激素重塑以模拟甲状腺疾病患者体内循环糖型的促甲状腺激素(TSH)免疫检测新校准品的可行性研究。
Clin Chem. 2006 Feb;52(2):286-97. doi: 10.1373/clinchem.2005.058172. Epub 2005 Nov 23.
9
Discrepancies between thyrotropin (TSH) measurement by four sensitive immunometric assays.四种灵敏免疫测定法检测促甲状腺激素(TSH)结果的差异。
Clin Chim Acta. 1997 Mar 18;259(1-2):117-28. doi: 10.1016/s0009-8981(96)06478-9.
10
Clinical significance of a low concentration of thyrotropin: five immunometric "kit" assays compared.低浓度促甲状腺激素的临床意义:五种免疫测定“试剂盒”检测方法的比较
Clin Chem. 1987 Jul;33(7):1237-41.