Suppr超能文献

在活体马中用二维超声心动图测量心脏尺寸。

Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse.

作者信息

Voros K, Holmes J R, Gibbs C

机构信息

Department of Veterinary Surgery, University of Bristol, School of Veterinary Science, Langford, UK.

出版信息

Equine Vet J. 1991 Nov;23(6):461-5. doi: 10.1111/j.2042-3306.1991.tb03762.x.

Abstract

Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-diastole (Ed) and/or end-systole (Es). Fractional shortening (FS) of the left ventricle and end-systolic left atrial to aortic ratio (LAD-Es:AoD-Es) also were calculated. Echocardiographic data were related to body weight by linear regression analysis. Intra-observer variability was checked in five horses by measuring each parameter during each of 10 consecutive cardiac cycles. The 2DE data were compared with M-mode values in published reports. In the 18 horses whose weight did not exceed 551 kg, repeatable recordings of good quality were obtained, and 2DE measurements could be made using intra-cardiac reference points. Increasing body weight proved to impose substantial limitations on measurements taken with the available machine and transducer. This problem might be overcome by using probes of lower frequency or equipment with higher quality image display at greater depth. The following parameters correlated significantly to body weight: VSTh-Es (r = 0.69; P less than 0.01). AoD-Es (r = 0.64; P less than 0.01) and CTA-Es (r = 0.84; P less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

对22匹未使用镇静剂的纯种马和部分纯种马进行了二维超声心动图(2DE)检查,这些马体重在411至650千克之间,目的是建立2DE测量的正常参考值。在检查过程中,动物站立不动,使用3.5兆赫机械扇形换能器,通过不同的换能器位置和断层平面进行检查。在心室舒张末期(Ed)和/或收缩末期(Es)测定右心室直径(RVD)、室间隔厚度(VSTh)、主动脉直径(AoD)、左心室腱索腔面积(CTA)、左心室直径(LVD)和左心房直径(LAD)。还计算了左心室缩短分数(FS)和收缩末期左心房与主动脉比值(LAD-Es:AoD-Es)。通过线性回归分析将超声心动图数据与体重相关联。通过在10个连续心动周期的每个周期中测量5匹马的每个参数来检查观察者内变异性。将2DE数据与已发表报告中的M型值进行比较。在体重不超过551千克的18匹马中,获得了质量良好的可重复记录,并且可以使用心内参考点进行2DE测量。事实证明,体重增加对使用现有机器和换能器进行的测量造成了很大限制。使用较低频率的探头或具有更高质量图像显示且深度更大的设备可能会克服这个问题。以下参数与体重显著相关:VSTh-Es(r = 0.69;P小于0.01)、AoD-Es(r = 0.64;P小于0.01)和CTA-Es(r = 0.84;P小于0.001)。(摘要截短至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验