Fiume A, Belletti S
Servizio di Fisica Sanitaria, Spedali Civili, Brescia.
Radiol Med. 1991 Nov;82(5):664-70.
Lipowitz's metal is widely employed in radiotherapy to create shielding blocks and compensators for X- and gamma-rays. Its effect in modifying radiation beams cannot be evaluated in a simple manner: therefore, in our opinion, an experimental approach to the problem is the most suitable one. Attenuation for Lipowitz's metal and lead was measured in some different geometrical setups, for a 5 MV linac and a 60Co unit. Transmitted fraction vs attenuator thickness curves were obtained. The influence of attenuators on depth-dose curves in a phantom was also evaluated: the results confirm the need to use data obtained in conditions as close as possible to the operative ones, in treatment planning as well as in studying and realizing calculation models.
利波维茨合金在放射治疗中被广泛用于制造X射线和γ射线的屏蔽块及补偿器。其对辐射束的修正效果无法以简单方式评估:因此,我们认为,针对该问题采用实验方法是最合适的。针对一台5兆伏直线加速器和一台钴60装置,在一些不同的几何设置下测量了利波维茨合金和铅的衰减。获得了透射分数与衰减器厚度的曲线。还评估了衰减器对模体中深度剂量曲线的影响:结果证实,在治疗计划以及研究和实现计算模型时,需要使用在尽可能接近实际操作条件下获得的数据。