Segers Patrick, Rietzschel Ernst R, De Buyzere Marc L, De Bacquer Dirk, Van Bortel Luc M, De Backer Guy, Gillebert Thierry C, Verdonck Pascal R
Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, B-9000 Gent, Belgium.
Physiol Meas. 2007 Sep;28(9):1045-56. doi: 10.1088/0967-3334/28/9/006. Epub 2007 Aug 21.
Assessment of timing and magnitude of wave reflection is ideally based on wave separation analysis (WSA). In clinical practice, however, waveform analysis (WFA) is often used to study wave reflection, with different coexisting approaches to assess 'landmarks' on the waveform which are indicative for return of the reflected wave. The aim of this work was to compare WSA and WFA. Data were obtained from 2132 subjects (1093 women) aged between 35 and 56 and free from overt cardiovascular disease. Carotid pressure and aortic flow waveforms, and carotid-femoral pulse wave velocity were measured non-invasively. WSA yielded the timing of return of reflected wave (T(f-b)), the ratio of forward and backward pressure wave (P(b)/P(f)), and the effective length of the arterial tree (L(eff)). WFA resulted in identification of the shoulder (T(sho)) or inflection point (T(inf)) as landmark points, with subsequently derived augmentation index and L(eff) (AIx(sho) and L(eff,sho), AIx(inf) and L(eff,inf), respectively). (i) Neither T(inf) nor T(sho) corresponded with the timing obtained from WSA. (ii) Measurements of L(eff) were found to decrease with age (conforming with current physiological insights) whilst L(eff,inf) was found to increase with age in women, and mixed results were obtained for L(eff,sho). (iii) Both AIx(inf) and AIx(sho) showed a persistent gender difference which was not present in P(b)/P(f). Using the pressure at T(f-b) to calculate AIx, the systematic gender difference in AIx(f-b) was greatly reduced. Analysis of pressure wave reflection is optimally based on measurement of pressure and flow, rather than on waveform analysis alone.
理想情况下,基于波分离分析(WSA)来评估波反射的时间和幅度。然而,在临床实践中,波形分析(WFA)常被用于研究波反射,存在不同的共存方法来评估波形上指示反射波返回的“标志点”。这项工作的目的是比较WSA和WFA。数据来自2132名年龄在35至56岁之间且无明显心血管疾病的受试者(1093名女性)。无创测量颈动脉压力和主动脉血流波形以及颈股脉搏波速度。WSA得出反射波返回时间(T(f-b))、前后压力波比值(P(b)/P(f))以及动脉树的有效长度(L(eff))。WFA确定肩部(T(sho))或拐点(T(inf))为标志点,随后得出增强指数和L(eff)(分别为AIx(sho)和L(eff,sho)、AIx(inf)和L(eff,inf))。(i)T(inf)和T(sho)均与WSA得出的时间不对应。(ii)发现L(eff)的测量值随年龄下降(符合当前生理认识),而L(eff,inf)在女性中随年龄增加,L(eff,sho)的结果则不一致。(iii)AIx(inf)和AIx(sho)均显示出持续的性别差异,而P(b)/P(f)中不存在这种差异。使用T(f-b)处的压力计算AIx,AIx(f-b)中的系统性性别差异大大减小。压力波反射分析最好基于压力和流量的测量,而不是仅基于波形分析。