Suppr超能文献

在室温下保存4至7天的痰液标本上进行HIV检测的低特异性:一项盲法比较。

Low specificity of HIV-testing on sputum specimens kept at ambient temperatures for 4 to 7 days: a blinded comparison.

作者信息

Egwaga Saidi M, Chonde Timothy M, Matee Mecky I, Mfinanga Sayoki G, Ngowi Prosper E, Lwilla Fred, Cobelens Frank G J

机构信息

National Tuberculosis and Leprosy Program, Dar-es-Salaam, Tanzania.

出版信息

BMC Clin Pathol. 2007 Sep 19;7:8. doi: 10.1186/1472-6890-7-8.

Abstract

BACKGROUND

HIV testing on sputum using the QraQuick HIV1/2(R) assay has high sensitivity and specificity, and holds promise for application in tuberculosis surveys. Its performance under conditions that may occur during surveys in resource-poor countries is however, unknown. We assessed, in a blinded comparison with HIV serum testing, the sensitivity and specificity of the OraQuick(R) assay for detecting HIV antibody in sputum specimens kept at ambient temperature for up to 7 days, with and without decontaminant.

METHODS

Paired sputum and blood specimens from consecutively diagnosed smear-positive tuberculosis patients were tested with OraQuick(R) and 2 HIV-1/2 ELISA's. Sputum was tested within 24 hours of collection, split into 2 aliquots with and without addition of cetylpyridium chloride, and tested again after 4 and 7 days.

RESULTS

Complete data was available for 377/435 (87%) enrolled patients; 132 (35%) tested HIV positive on serum. The sensitivity of the sputum test was 94.7% (95% CI 89.4-97.8) on day 1, 93.2% on day 4 and 92.9% on day 7. The specificity was 92.9% (95% CI 88.9-95.8) on day 1, and declined to 76.7% on day 4 (p < 0.001) and to 62.7% on day 7 (p < 0.001). Adding cetylpyridium chloride further decreased the specificity to 67.8% on day 4 (p = 0.04) and to 49.6% on day 7 (p = 0.004).

CONCLUSION

Transportation of sputum specimens at ambient temperatures for 4 days or more, and addition of decontaminant, strongly affect the specificity of the OraQuick(R) assay. Unless applied within one day, this assay is not suitable for estimation of HIV-prevalence among tuberculosis patients in survey settings.

摘要

背景

使用QraQuick HIV1/2(R)检测法对痰液进行HIV检测具有较高的敏感性和特异性,有望应用于结核病调查。然而,其在资源匮乏国家调查期间可能出现的条件下的性能尚不清楚。我们通过与HIV血清检测进行盲法比较,评估了OraQuick(R)检测法在有或无去污剂的情况下,对在室温下保存长达7天的痰液标本中HIV抗体检测的敏感性和特异性。

方法

对连续诊断为涂片阳性结核病患者的配对痰液和血液标本进行OraQuick(R)和2种HIV-1/2 ELISA检测。痰液在采集后24小时内进行检测,分成两份,一份添加十六烷基氯化吡啶,另一份不添加,在4天和7天后再次检测。

结果

377/435(87%)名入组患者有完整数据;132名(35%)血清检测HIV呈阳性。痰液检测的敏感性在第1天为94.7%(95%CI 89.4 - 97.8),第4天为93.2%,第7天为92.9%。特异性在第1天为92.9%(95%CI 88.9 - 95.8),第4天降至76.7%(p < 0.001),第7天降至62.7%(p < 0.001)。添加十六烷基氯化吡啶进一步降低了特异性,第4天降至67.8%(p = 0.04),第7天降至49.6%(p = 0.004)。

结论

在室温下运输痰液标本4天或更长时间以及添加去污剂会强烈影响OraQuick(R)检测法的特异性。除非在一天内应用,否则该检测法不适用于在调查环境中估计结核病患者中的HIV流行率。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/da4d/2072942/7880e59c363d/1472-6890-7-8-1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验