Diffusion tensor imaging and tractography of median nerve: normative diffusion values.

作者信息

Kabakci Neslihan, Gürses Bengi, Firat Zeynep, Bayram Ali, Uluğ Aziz Müfit, Kovanlikaya Arzu, Kovanlikaya Ilhami

机构信息

Department of Radiology, Yeditepe University Hospital, Devlet Yolu Ankara Cad. 102-104, 34752 Kozyataği, Istanbul, Turkey.

出版信息

AJR Am J Roentgenol. 2007 Oct;189(4):923-7. doi: 10.2214/AJR.07.2423.

Abstract

OBJECTIVE

The purposes of this study were to visualize the human median nerve on diffusion tensor imaging and to determine the normal fractional anisotropy (FA) value and apparent diffusion coefficient (ADC) of the normal median nerve.

SUBJECTS AND METHODS

The wrists of 20 healthy volunteers and of two patients with carpel tunnel syndrome were examined with a 3-T MRI system with a standard eight-channel sensitivity-encoding head coil. Diffusion tensor imaging was performed with a spin-echo echo-planar sequence. A T1-weighted sequence was performed for anatomic reference. After tractography, the FA value and ADC of the whole nerve were calculated automatically. Manual focal measurements also were obtained at the levels of the flexor retinaculum, wrist, and forearm.

RESULTS

We visualized the median nerve with MR diffusion tensor tractography and followed the nerve for approximately 77.5 mm. We found the normative diffusion values of the median nerve were an FA of 0.709 +/- 0.046 (SD) and an ADC of 1.016 +/- 0.129 x 10(-3) mm2/s. There was a statistically significant difference between the FA values obtained at the level of the flexor retinaculum and the values obtained from the other parts of the median nerve (p < 0.0001). We found a decrease in FA value (p < 0.01) and an increase in ADC (p < 0.05) with advancing age.

CONCLUSION

The normative diffusion values of the human median nerve can be used as a reference in evaluation, diagnosis, and follow-up of entrapment, trauma, and regeneration of the median nerve.

摘要

目的

本研究的目的是在扩散张量成像上可视化人类正中神经,并确定正常正中神经的正常分数各向异性(FA)值和表观扩散系数(ADC)。

对象与方法

使用配备标准八通道灵敏度编码头部线圈的3-T MRI系统,对20名健康志愿者和两名腕管综合征患者的手腕进行检查。采用自旋回波平面回波序列进行扩散张量成像。采用T1加权序列进行解剖学参考。在进行纤维束成像后,自动计算整个神经的FA值和ADC。还在屈肌支持带、腕部和前臂水平进行手动局部测量。

结果

我们通过磁共振扩散张量纤维束成像可视化了正中神经,并追踪该神经约77.5毫米。我们发现正中神经的正常扩散值为FA为0.709±0.046(标准差),ADC为1.016±0.129×10⁻³平方毫米/秒。在屈肌支持带水平获得的FA值与正中神经其他部位获得的值之间存在统计学显著差异(p<0.0001)。我们发现随着年龄增长,FA值降低(p<0.01),ADC升高(p<0.05)。

结论

人类正中神经的正常扩散值可作为评估、诊断以及随访正中神经卡压、损伤和再生的参考。