Suppr超能文献

骨髓炎:用99mTC放射性标记单克隆抗体进行抗粒细胞闪烁扫描术用于诊断——荟萃分析

Osteomyelitis: antigranulocyte scintigraphy with 99mTC radiolabeled monoclonal antibodies for diagnosis-- meta-analysis.

作者信息

Pakos Emilios E, Koumoullis Harry D, Fotopoulos Andreas D, Ioannidis John P A

机构信息

Clinical Trials and Evidence-Based Medicine Unit, Department of Hygiene and Epidemiology, University Hospital of Ioannina School of Medicine, University Campus, Ioannina, Epirus 45110, Greece.

出版信息

Radiology. 2007 Dec;245(3):732-41. doi: 10.1148/radiol.2452061877. Epub 2007 Sep 26.

Abstract

PURPOSE

To perform a meta-analysis of the sensitivity and specificity of antigranulocyte scintigraphy with monoclonal antibodies (MoAbs) in the diagnosis of osteomyelitis across different patient groups and clinical settings.

MATERIALS AND METHODS

MEDLINE and EMBASE searches were conducted. Data on the diagnostic performance of antigranulocyte scintigraphy with MoAbs were combined. Weighted sensitivities and specificities were estimated by using a random-effects model that incorporated between-study heterogeneity and by constructing summary receiver operating characteristic (ROC) curves. The weighted positive and negative likelihood ratios (LRs) across studies were estimated. Data syntheses were performed for all patients and for various subgroups. The reference standard used in each individual study was accepted.

RESULTS

Nineteen nonoverlapping studies with a total of 714 examinations and reference standards of cell culture, histologic examination, clinical follow-up, and radiologic examination were eligible. The independent random-effects summary estimates of sensitivity and specificity were 81% (95% confidence interval [CI]: 70%, 88%) and 77% (95% CI: 66%, 86%), respectively, with statistically significant between-study heterogeneity (exact P < .001 for both metrics). In the summary ROC curve, a sensitivity of 81% corresponded to a specificity of 86%, and a specificity of 77% corresponded to a sensitivity of 87%. The weighted positive LR was 3.02 (95% CI: 2.07, 4.42), and the weighted negative LR was 0.26 (95% CI: 0.17, 0.39), with statistically significant between-study heterogeneity (exact P < .001 for both metrics). Sensitivity was better for peripheral than for axial skeleton lesions (87% vs 53%).

CONCLUSION

Antigranulocyte scintigraphy with MoAbs has a sensitivity of 81% and a specificity of 77% in the diagnosis of osteomyelitis.

摘要

目的

对使用单克隆抗体(MoAbs)的抗粒细胞闪烁扫描术在不同患者群体和临床环境中诊断骨髓炎的敏感性和特异性进行荟萃分析。

材料与方法

进行了MEDLINE和EMBASE检索。汇总了使用MoAbs的抗粒细胞闪烁扫描术的诊断性能数据。采用纳入研究间异质性的随机效应模型并构建汇总受试者工作特征(ROC)曲线,估计加权敏感性和特异性。估计各研究的加权阳性和阴性似然比(LRs)。对所有患者和各个亚组进行数据综合分析。接受各独立研究中使用的参考标准。

结果

19项不重叠研究共714次检查符合要求,参考标准包括细胞培养、组织学检查、临床随访和放射学检查。敏感性和特异性的独立随机效应汇总估计分别为81%(95%置信区间[CI]:70%,88%)和77%(95%CI:66%,86%),研究间存在统计学显著异质性(两个指标的精确P均<.001)。在汇总ROC曲线中,81%的敏感性对应86%的特异性,77%的特异性对应87%的敏感性。加权阳性LR为3.02(95%CI:2.07,4.42),加权阴性LR为0.26(95%CI:0.17,0.39),研究间存在统计学显著异质性(两个指标的精确P均<.001)。外周骨骼病变的敏感性优于轴向骨骼病变(87%对53%)。

结论

使用MoAbs的抗粒细胞闪烁扫描术诊断骨髓炎的敏感性为81%,特异性为77%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验