Parkin A, Robinson P J, Martinez D, Wilkinson D, Kester R C
Department of Medical Physics, St James's University Hospital, Leeds, UK.
Nucl Med Commun. 1991 Oct;12(10):835-51. doi: 10.1097/00006231-199110000-00003.
Radionuclide limb blood flow measurements using 99Tcm-labelled human serum albumin and a gamma camera have been performed on normal volunteers and on patients with suspected or confirmed peripheral arterial disease. The normal range of flow was found to be 10.0-22.3 ml per 100 ml tissue per min. Flow in the symptomatic legs of patients with arterial disease varied from 9.0 ml per 100 ml tissue per min in mild claudication to less than 1.0 ml per 100 ml tissue per min in rest pain. The technique has been used as an initial screening procedure, to resolve diagnostic problems, to measure objectively the treatment response and to assess patients with critical ischaemia. The results of 1100 measurements are reported and the clinical utility in routine vascular surgical practice is discussed.
已使用99锝标记的人血清白蛋白和γ相机对正常志愿者以及疑似或确诊外周动脉疾病的患者进行了放射性核素肢体血流测量。发现正常血流范围为每分钟每100毫升组织10.0 - 22.3毫升。动脉疾病患者有症状腿部的血流变化范围为,轻度间歇性跛行时每分钟每100毫升组织9.0毫升,静息痛时每分钟每100毫升组织少于1.0毫升。该技术已被用作初始筛查程序,以解决诊断问题,客观测量治疗反应并评估严重缺血患者。报告了1100次测量的结果,并讨论了其在常规血管外科实践中的临床应用。