Wang Ya Xing, Xu Liang, Zhang Rong Xiu, Jonas Jost B
Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital University of Medical Science, Beijing, China.
Arch Ophthalmol. 2007 Oct;125(10):1402-6. doi: 10.1001/archopht.125.10.1402.
To determine the predictive value of frequency-doubling threshold perimetry for glaucoma in a population-based study.
The Beijing Eye Study, a population-based study on subjects 40 years or older, included an ophthalmic examination with fundus photography and frequency-doubling threshold perimetry. Glaucoma was defined by a glaucomatous optic disc appearance.
The study population consisted of 4349 subjects (8615 eyes). Among 207 glaucomatous eyes (2.4%), 74 (35.7%) did not show any abnormality on frequency-doubling threshold perimetry, suggesting a diagnostic sensitivity of 64.3%. In the total study population, a visual field defect was found in 905 eyes (10.5%). In 133 (14.7%) of these eyes, a glaucomatous appearance of the optic disc was detected, and 772 eyes (85.3%) had a nonglaucomatous optic disc appearance (either normal or with nonglaucomatous optic nerve damage, retinal disease, corneal disease, or cataract). For 450 eyes (49.7%) with a visual field defect, the cause of the perimetric defect was not detected.
In a population-based study, frequency-doubling threshold perimetry has a sensitivity of about 64% to detect glaucoma. If the result is abnormal, the probability of glaucoma is about 15%. When results of frequency-doubling threshold perimetry are abnormal, the cause of the visual field defect may not be detectable in 50% of subjects.
在一项基于人群的研究中确定倍频视野计对青光眼的预测价值。
北京眼病研究是一项针对40岁及以上人群的基于人群的研究,包括眼底照相和倍频视野计的眼科检查。青光眼由青光眼性视盘外观定义。
研究人群包括4349名受试者(8615只眼)。在207只青光眼眼中(2.4%),74只(35.7%)在倍频视野计检查中未显示任何异常,提示诊断敏感性为64.3%。在整个研究人群中,905只眼(10.5%)发现有视野缺损。在这些眼中,133只(14.7%)检测到青光眼性视盘外观,772只眼(85.3%)有非青光眼性视盘外观(正常或伴有非青光眼性视神经损伤、视网膜疾病、角膜疾病或白内障)。对于450只(49.7%)有视野缺损的眼,未检测到视野缺损的原因。
在一项基于人群的研究中,倍频视野计检测青光眼的敏感性约为64%。如果结果异常,青光眼的概率约为15%。当倍频视野计结果异常时,50%的受试者可能无法检测到视野缺损的原因。