Eisenberg R L, Mani R L, McDonald E J
AJR Am J Roentgenol. 1976 Apr;126(4):814-6. doi: 10.2214/ajr.126.4.814.
A search of the literature revealed no documentation of the complication rate associated with percutaneous catheterization of aorto-femoral bypass grafts in the arteriographic evaluation of graft patency. The authors compared the complication rates of 29 consecutive arteriograms performed through grafts (Group I) with 40 arteriograms performed on non patients (Group II). Neither group had any significant complications, indicating the safety of percutaneous catheterization of the graft site.