Good agreement between bioelectrical impedance and dual-energy X-ray absorptiometry for estimating changes in body composition during weight loss in overweight young women.

作者信息

Thomson Rebecca, Brinkworth Grant D, Buckley Jonathan D, Noakes Manny, Clifton Peter M

机构信息

CSIRO Human Nutrition, PO Box 10041 BC, Adelaide 5000, Australia.

出版信息

Clin Nutr. 2007 Dec;26(6):771-7. doi: 10.1016/j.clnu.2007.08.003. Epub 2007 Oct 23.

Abstract

AIMS

To compare estimations of body composition using two different methods of bioelectrical impedance analysis (BIA) with dual X-ray absorptiometry (DXA) for estimating body composition during weight loss in overweight and obese young females.

METHODS

Twenty-four overweight or obese females (age 29.5+/-6.1 years, BMI 36.4+/-4.3 kg/m(2)) had body composition assessed using single-frequency (Tanita Ultimate Scale; SF-BIA) and multi-frequency (Impedimed SFB7; MF-BIA) BIA and DXA before and after a 10-week weight loss intervention.

RESULTS

MF-BIA estimates of body composition showed good absolute agreement with DXA, as evidenced by the small biases in the estimation of fat free mass (FFM), fat mass (FM) and percentage body fat (BF%); however, the limits of agreement for each variable were wide (bias +/-1.96 standard deviation; FFM -1.6+/-6.5 kg, FM 1.6+/-6.5 kg, BF% 1.4+/-6.3%). SF-BIA exhibited a larger bias with wide limits of agreement (FFM 3.8+/-9.1 kg, FM -3.8+/-9.1 kg, BF% -4.37+/-10.3%). During weight loss the values provided by MF-BIA and SF-BIA were not significantly different from DXA (p> or =0.89) due to small bias and the limits of agreement were narrow (MF-BIA: FFM -0.01+/-3.74 kg, FM 0.01+/-3.74 kg, BF% 0.22+/-3.40%; SF-BIA: FFM 0.40+/-3.92 kg, FM -0.40+/-3.92 kg, BF% 0.25+/-3.40%).

CONCLUSION

Compared with DXA, both the MF-BIA and SF-BIA accurately assessed changes in body composition with weight loss but, compared with SF-BIA, MF-BIA provided superior cross-sectional estimates of body composition.

摘要

目的

比较两种不同的生物电阻抗分析(BIA)方法与双能X线吸收法(DXA)对超重和肥胖年轻女性体重减轻期间身体成分的估计。

方法

24名超重或肥胖女性(年龄29.5±6.1岁,BMI 36.4±4.3kg/m²)在进行为期10周的体重减轻干预前后,使用单频(Tanita Ultimate Scale;SF-BIA)和多频(Impedimed SFB7;MF-BIA)BIA以及DXA评估身体成分。

结果

MF-BIA对身体成分的估计与DXA显示出良好的绝对一致性,无脂肪量(FFM)、脂肪量(FM)和体脂百分比(BF%)估计中的小偏差证明了这一点;然而,每个变量的一致性界限较宽(偏差±1.96标准差;FFM -1.6±6.5kg,FM 1.6±6.5kg,BF% 1.4±6.3%)。SF-BIA表现出较大偏差且一致性界限较宽(FFM 3.8±9.1kg,FM -3.8±9.1kg,BF% -4.37±-10.3%)。在体重减轻期间,由于偏差小,MF-BIA和SF-BIA提供的值与DXA无显著差异(p≥0.89),且一致性界限较窄(MF-BIA:FFM -0.01±3.74kg,FM 0.01±3.74kg,BF% 0.22±3.40%;SF-BIA:FFM 0.40±3.92kg,FM -0.40±3.92kg,BF% 0.25±3.40%)。

结论

与DXA相比,MF-BIA和SF-BIA都能准确评估体重减轻时身体成分的变化,但与SF-BIA相比,MF-BIA对身体成分的横断面估计更优。