Suppr超能文献

通过多巴酚丁胺负荷201铊心肌单光子发射计算机断层扫描(SPECT)的ST段/心率斜率及201铊心肌显像增强对女性冠心病的诊断

Enhanced diagnosis of coronary artery disease in women by dobutamine thallium-201 ST-segment/heart rate slope and thallium-201 myocardial SPECT.

作者信息

Yeih Dong-Feng, Huang Por-Jau, Ho Yi-Lwun

机构信息

Department of Cardiology, Far Eastern Memorial Hospital, Pan-Chiao, Taiwan.

出版信息

J Formos Med Assoc. 2007 Oct;106(10):832-9. doi: 10.1016/S0929-6646(08)60048-0.

Abstract

BACKGROUND/PURPOSE: The diagnosis of coronary artery disease (CAD) in women presents a great challenge because of poor exercise capacity and inadequate heart rate response during stress test. The clinical significance of stress-related ST-segment/heart rate slope (ST/HR slope) value for evaluating CAD in women remains controversial. Therefore, we conducted the present study to assess the diagnostic performance of dobutamine ST/HR slope in women, compared with myocardial perfusion study using thallium-201 single-photon emission computed tomography (Tl-201 SPECT).

METHODS

A total of 51 female patients with suspected CAD underwent simultaneous 12-lead electrocardiographic recording during 3-minute stages of dobutamine infusion as well as Tl-201 SPECT, and coronary angiography was performed within 2 weeks post Tl-201 SPECT. The sensitivity, specificity, positive predictive value and negative predictive value of dobutamine ST/HR slope and Tl-201 SPECT were assessed, and the results of coronary angiography were used as a gold standard.

RESULTS

The sensitivity, specificity and accuracy of dobutamine ST/HR slope in detecting CAD were 43%, 83% and 61%, and those of Tl-201 SPECT were 71%, 87% and 78%, respectively. However, using both positive results of Tl-201 SPECT and ST/HR slope for detecting CAD, the diagnostic specificity increased from 87% to 96%. Using both negative results of Tl-201 SPECT and ST/HR slope to exclude CAD, the negative predictive value increased from 71% to 85%. The accuracy of dobutamine ST/HR slope in detecting CAD was not affected by the use of beta-blockers.

CONCLUSION

Dobutamine ST/HR slope is less sensitive and less accurate than Tl-201 SPECT for detecting CAD in women. However, it adds diagnostic benefit to Tl-201 SPECT with only a little extra calculation.

摘要

背景/目的:由于女性运动能力差以及在压力测试期间心率反应不足,冠状动脉疾病(CAD)的诊断面临巨大挑战。压力相关ST段/心率斜率(ST/HR斜率)值在评估女性CAD中的临床意义仍存在争议。因此,我们进行了本研究,以评估多巴酚丁胺ST/HR斜率在女性中的诊断性能,并与使用铊-201单光子发射计算机断层扫描(Tl-201 SPECT)的心肌灌注研究进行比较。

方法

共有51例疑似CAD的女性患者在多巴酚丁胺输注的3分钟阶段以及Tl-201 SPECT期间同时进行12导联心电图记录,并在Tl-201 SPECT后2周内进行冠状动脉造影。评估多巴酚丁胺ST/HR斜率和Tl-201 SPECT的敏感性、特异性、阳性预测值和阴性预测值,并将冠状动脉造影结果用作金标准。

结果

多巴酚丁胺ST/HR斜率检测CAD的敏感性、特异性和准确性分别为43%、83%和61%,而Tl-201 SPECT的敏感性、特异性和准确性分别为71%、87%和78%。然而,同时使用Tl-201 SPECT和ST/HR斜率的阳性结果检测CAD时,诊断特异性从87%提高到96%。同时使用Tl-201 SPECT和ST/HR斜率的阴性结果排除CAD时,阴性预测值从71%提高到85%。多巴酚丁胺ST/HR斜率检测CAD的准确性不受β受体阻滞剂使用的影响。

结论

多巴酚丁胺ST/HR斜率在检测女性CAD方面比Tl-201 SPECT敏感性更低、准确性更差。然而,只需进行少量额外计算,它就能为Tl-201 SPECT增加诊断价值。