Daldal Alper, Odabasi Onur, Serbetcioglu Bulent
Department of Otorhinolaryngology, Acipayam Goverment Hospital, Denizli, Turkey.
Otolaryngol Head Neck Surg. 2007 Nov;137(5):747-52. doi: 10.1016/j.otohns.2007.05.068.
The purpose of this study was to investigate the effectiveness of intratympanic dexamethasone injection as a protection agent against cisplatin-induced ototoxicity.
The four groups of guinea pigs were injected as follows: 1) cisplatin, 2) intratympanic dexamethasone, 3) cisplatin following intratympanic dexamethasone, and 4) cisplatin after intratympanic saline. Before and 3 days following injections, the ototoxic effect was measured with distortion product otoacoustic emissions (DPOAEs).
The DPOAEs amplitudes and signal-to-noise ratio (SNR) values at 1 to 6 kHz frequencies for group 1 animals after injections significantly decreased over those before injections (P < 0.05). In group 2, there were no significant differences in DPOAE amplitude and SNR values between before and after intratympanic dexamethasone injections (P > 0.05). Considering group 3, there were also no significant differences in DPOAEs amplitudes and SNR values before and after of dexamethasone and cisplatin injections (P > 0.05).
Intratympanic dexamethasone injection did not cause any ototoxic effect; in contrast, it might have a significant protective effect after cisplatin injection.
本研究旨在探讨鼓室内注射地塞米松作为顺铂所致耳毒性保护剂的有效性。
将四组豚鼠按如下方式注射:1)顺铂,2)鼓室内注射地塞米松,3)鼓室内注射地塞米松后注射顺铂,4)鼓室内注射生理盐水后注射顺铂。在注射前及注射后3天,用畸变产物耳声发射(DPOAE)测量耳毒性效应。
第1组动物注射后1至6kHz频率处的DPOAE振幅和信噪比(SNR)值较注射前显著降低(P<0.05)。第2组,鼓室内注射地塞米松前后DPOAE振幅和SNR值无显著差异(P>0.05)。对于第3组,地塞米松和顺铂注射前后DPOAE振幅和SNR值也无显著差异(P>0.05)。
鼓室内注射地塞米松未引起任何耳毒性效应;相反,在注射顺铂后可能具有显著的保护作用。