BACKGROUND AND STUDY AIMS

Reliable closure of the transluminal incision is the crucial step for natural orifice transluminal endoscopic surgery (NOTES) procedures. The aim of this study was to evaluate the feasibility and effectiveness of transgastric access closure with a flexible stapling device in a porcine survival model.

PATIENTS AND METHODS

We carried out four experiments (two sterile and two nonsterile) on 50 kg pigs. The endoscope was passed through a gastrotomy made with a needle knife and an 18-mm controlled radial expansion dilating balloon. After peritoneoscopy, a flexible linear stapling device (NOLC60, Power Medical Interventions, Langhorne, Pennsylvania, USA) was perorally advanced over a guide wire into the stomach, positioned under endoscopic guidance, and opened to include the site of gastrotomy between its two arms; four rows of staples were fired. One animal was sacrificed 24 hours after the procedure (progression of pre-existing pneumonia). The remaining animals were survived for 1 week and then underwent repeat endoscopy and postmortem examination.

RESULTS

Peroral delivery and positioning of the stapling device involved some technical difficulties, mostly due to the short length (60 cm) of the stapling device. The stapler provided complete leak-resistant gastric closure in all pigs. None of the surviving animals had any clinical signs of infection. Necropsy demonstrated an intact staple line with full-thickness healing of the gastrotomy in all animals. Histologic examination confirmed healing, but also revealed intramural micro-abscesses within the gastric wall after nonsterile procedure.

CONCLUSIONS

Gastrotomy closure with a perorally delivered flexible stapling device created a leak-resistant transmural line of staples followed by full-thickness healing of the gastric wall incision. Increasing the length of the instrument and adding device articulation will further facilitate its use for NOTES procedures.

摘要

背景与研究目的

经腔切口的可靠闭合是自然腔道内镜手术(NOTES)操作的关键步骤。本研究旨在评估在猪存活模型中使用柔性吻合器经胃入路闭合的可行性和有效性。

患者与方法

我们对体重50千克的猪进行了四项实验(两项无菌实验和两项非无菌实验)。通过针刀和18毫米可控径向扩张球囊制作胃切开术,将内镜经由此处插入。腹腔镜检查后,将柔性线性吻合器(NOLC60,美国宾夕法尼亚州兰霍恩市Power Medical Interventions公司)经口沿导丝推进至胃内,在内镜引导下定位,张开使其两臂之间包含胃切开部位,击发四排吻合钉。术后24小时处死1只动物(因原有肺炎病情进展)。其余动物存活1周,然后接受重复内镜检查和尸检。

结果

吻合器的经口递送和定位存在一些技术难题,主要是因为吻合器长度较短(60厘米)。吻合器在所有猪中均实现了胃的完全抗渗漏闭合。所有存活动物均无任何感染的临床体征。尸检显示所有动物的吻合钉线完整,胃切开处全层愈合。组织学检查证实愈合,但也显示非无菌操作后胃壁内存在壁内微脓肿。

结论

使用经口递送的柔性吻合器闭合胃切开术可形成抗渗漏的跨壁吻合钉线,随后胃壁切口实现全层愈合。增加器械长度并增加器械关节活动度将进一步便于其在NOTES手术中的应用。