使用嵌入衣物中的纺织电极测量肌电活动。

Measurement of EMG activity with textile electrodes embedded into clothing.

作者信息

Finni T, Hu M, Kettunen P, Vilavuo T, Cheng S

机构信息

Neuromuscular Research Center, Department of Biology of Physical Activity, PO Box 35 (VIV), FI-40014 University of Jyväskylä, Finland.

出版信息

Physiol Meas. 2007 Nov;28(11):1405-19. doi: 10.1088/0967-3334/28/11/007. Epub 2007 Oct 12.

Abstract

Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 persons for each). Within-session repeatability (the coefficient of variation CV%, n=10) was calculated from five repetitions of 60% maximum voluntary contraction (MVC). The day-to-day repeatability (n=8) was assessed by measuring three different isometric force levels on five consecutive days. The feasibility of the textile electrodes in field conditions was assessed during a maximal treadmill test (n=28). Bland-Altman plots showed a good agreement within 2SD between the textile and traditional electrodes, demonstrating that the textile electrodes provide similar information on the EMG signal amplitude to the traditional electrodes. The within-session CV ranged from 13% to 21% in both the textile and traditional electrodes. The day-to-day CV was smaller, ranging from 4% to 11% for the textile electrodes. A similar relationship (r(2)=0.5) was found between muscle strength and the EMG of traditional and textile electrodes. The feasibility study showed that the textile electrode technique can potentially make EMG measurements very easy in field conditions. This study indicates that textile electrodes embedded into shorts is a valid and feasible method for assessing the average rectified value of EMG.

摘要

新型纺织电极已被开发出来,这种电极可以嵌入运动服装中,用于测量平均整流肌电图(EMG),以便于在现场测试和临床环境中使用。本研究的目的是评估这种新产品测量平均整流EMG的有效性、可靠性和可行性。通过在双侧等长伸膝运动中比较双极纺织电极(42平方厘米)和传统双极表面电极(1.32平方厘米)在两个电极位置(A:两个电极位于同一位置,B:传统电极根据SENIAM放置在各个肌肉上,每组10人)时的信号来测试有效性。通过60%最大自主收缩(MVC)的五次重复计算组内重复性(变异系数CV%,n = 10)。通过连续五天测量三种不同的等长力水平来评估每日重复性(n = 8)。在最大跑步机测试期间评估纺织电极在现场条件下的可行性(n = 28)。布兰德-奥特曼图显示纺织电极和传统电极在2SD范围内具有良好的一致性,表明纺织电极在EMG信号幅度方面提供了与传统电极相似的信息。纺织电极和传统电极的组内CV范围均为13%至21%。纺织电极的每日CV较小,范围为4%至11%。在传统电极和纺织电极的肌肉力量与EMG之间发现了相似的关系(r² = 0.5)。可行性研究表明,纺织电极技术有可能使现场条件下的EMG测量变得非常容易。本研究表明,嵌入短裤的纺织电极是评估EMG平均整流值的一种有效且可行的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验