Suppr超能文献

使用GuardianRT进行实时连续血糖监测:从研究到临床实践。

Real-time continuous glucose monitoring using GuardianRT: from research to clinical practice.

作者信息

Tubiana-Rufi N, Riveline J-P, Dardari D

机构信息

Diabetes and Endocrinology Department, Robert Debré Hospital, APHP, 48, boulevard Sérurier, 75019 Paris, France.

出版信息

Diabetes Metab. 2007 Dec;33(6):415-20. doi: 10.1016/j.diabet.2007.05.003. Epub 2007 Nov 7.

Abstract

The limited number of self-monitoring blood glucose measurements is an obstacle for good metabolic control in patients with type 1 diabetes. However, continuous glucose measurement with real-time data and alarms is a recent technology that promises to improve the efficacy of treatment in diabetic patients. GuardianRT uses a continuous telemetry display of real-time glucose values, and automatic alerts at preset hypo- and hyperglycaemic levels. Three calibrations a day are required, and the sensor must be changed every three days. The GuardControl study showed that, within three months, real-time continuous glucose monitoring with the GuardianRT led to significantly improved HbA1c values in 162 poorly controlled patients (children and adults) with type 1 diabetes despite intensive insulin therapy. The continuous availability of glucose measurements permitted the patients to adjust their own insulin doses, food intake and physical activity and, thus, improve their glycaemic control. This report summarizes the available data on this tool and details how best to use this state-of-the-art modality in diabetic patients in clinical practice.

摘要

自我血糖监测次数有限是1型糖尿病患者实现良好代谢控制的一个障碍。然而,具有实时数据和警报功能的连续血糖监测是一项最新技术,有望提高糖尿病患者的治疗效果。GuardianRT采用实时血糖值的连续遥测显示,并在预设的低血糖和高血糖水平时自动发出警报。每天需要进行三次校准,且传感器必须每三天更换一次。GuardControl研究表明,在三个月内,对于162名尽管接受了强化胰岛素治疗但血糖控制不佳的1型糖尿病患者(儿童和成人),使用GuardianRT进行实时连续血糖监测可显著改善糖化血红蛋白(HbA1c)值。血糖测量的持续可用性使患者能够调整自己的胰岛素剂量、食物摄入量和身体活动,从而改善血糖控制。本报告总结了关于该工具的现有数据,并详细说明了在临床实践中如何最好地在糖尿病患者中使用这种先进的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验